REVOLUTION SIGNAL OUTPUT CONNECTION
The wiring harness of the AEB518N timing advance processor features a revo-
lution signal output (brown wire) that can be used by injection or feedback
systems as an engine revolutions reference.
CAUTION:
If the revolution signal output (brown wire) is connected to a
feedback or injection control unit, set the parameters as displayed below
(using a PC and the software).
FEEDBACK SYSTEMS
SET:
Ignition type: Dual coil
Type of RPM signal: Standard
INJECTION SYSTEMS
SET:
Type of revolution signal: Standard
Ignition type: Dual coil
19