Backsplash
Locator Line
2" (5cm)
Min.
Divide Escutcheon
Diameter in Half,
Then Add 1/4" (6mm)
1. Preparation
Install the water supplies and drain piping according to the
roughing-in information.
Wall-Mount Bracket Installations
Install the lavatory according to the instructions packed with the
bracket.
Continue to the "Install the Lavatory" section.
Self-Rimming Installations
Determine the faucet centerline location. Consider the faucet and
handle escutcheon diameters, the length of the spout, and the
clearance between the spout and the lavatory rim.
Calculate the faucet centerline measurement by first dividing the
escutcheon diameter by 2, and then add 1/4" (6mm) to the result.
If necessary, round the calculation up to the nearest 1/16" (2mm).
Carefully draw the calculated faucet centerline on the cut-out
template. Choose the most suitable location based upon the
following factors:
• compliance with all local plumbing codes
• minimum 2" (5.1cm) distance from the water stream to the
lavatory rim edge. This is important to ensure adequate clearance
for hand washing
1018374-2-A
Faucet
Centerline
Countertop
Cut-Out
Template
4
1" (2.5cm) Min.
Clearance
1/4" (6mm)
Min.
2" (5cm)
Min.