3. When using a hose without thread: slide an appropriate
ES
hose clamp onto the hose.
4. Push the hose (inner diameter 25mm or 32mm) onto the
reducer (7) all the way to the stop. (see fig. 5)
PT
5. Affix the hose by means of the hose clamp.
6. When using a hose with internal thread (1''): screw the
hose connection onto the reducer 7. (see fig .6)
EN
7. Alternatively, you can also screw a hose with Internal
threading (1 ½") directly onto the elbow (8).
FR
Pipe
If possible, screw the pipe directly into the connection with 1 ½"
internal thread (6) or use a suitable adapter. (see fig. 7)
Adjusting the float switch
The device comes equipped with a float switch (4) which switches
the device on or off automatically according to the water level.
Check the float switch (4) for proper functioning at regular intervals.
Instruction manual
fig. 6
SWITCHING POINT
Height for switch-on
Height for switch-off
fig. 7
WATER LEVEL
Ref. 08792
Approx. 500mm
Approx. 250mm
Ref. 08792