Connect the Breakout Cable

The camera's PWR connector supplies power to the camera and provides access to
the camera's acquisition trigger and strobe output.
CAUTION:
To reduce emissions, connect the far end of the Breakout cable
shield to frame ground.
Note:
I/O wiring or adjustments to I/O devices should be performed when
l
the camera is not receiving power.
Exposed wires can be cut short or wire ends trimmed, and the wires
l
tied back using a tie made of non-conductive material. Keep all bare
wires separated from the +24VDC wire.
1. Remove power from the camera.
2. Remove power from the vision controller.
3. Optionally, connect the I/O wires to an appropriate device (for example, a
trigger sensor or strobe light).
4. Attach the Breakout cable's +24VDC (Red wire) and GND (Black wire) to
the corresponding terminals on the power supply.
CAUTION:
observe the polarity shown.
5. Connect the Breakout cable's M12 connector to the camera's PWR
connector.
Never connect voltages other than 24VDC. Always