Connect the Breakout Cable

CAUTION:
To reduce emissions, connect the far end of the Breakout cable
shield to frame ground.
Note:
Perform wiring or adjustments to I/O devices when the vision system
l
is not receiving power.
You can cut exposed wires short or trim wire ends. You also can tie
l
the wires back if you use a tie made of non-conductive material. Keep
bare wires separated from the +24VDC wire.
When using the 15 meter Breakout cable, full 24VDC voltage must be
l
maintained at the input leads of the Breakout cable when the vision
system is operating.
1. Verify that the 24VDC power supply is unplugged and not receiving power.
2. Optionally, connect the I/O wires to an appropriate device (for example, a
PLC or a trigger sensor).
3. Attach the Breakout cable's +24VDC (Red wire) and GND (Black wire) to
the corresponding terminals on the power supply.
CAUTION:
observe the polarity shown.
4. Connect the Breakout cable's M12 connector to the vision system PWR
connector.
5. Restore power to the 24VDC power supply and turn it on if necessary.
Never connect voltages other than 24VDC. Always
14