3. Ceiling Fan Assembly
NOTE: If Installing the Ceiling Fan without the LED Light Fixture Assembly, Skip
Sections 3.5 - 3.6 and Complete 3.7 - 3.15.
Section 7, Installation of No-Light Cover (Optional) will replace the LED Shade.
3.5
Engage the Fan Motor 2-Pin Wire Connector into the
2-pin Wire Connector of the LED Light Fixture Assembly
(Figure 5).
The connection is complete when you hear a soft click.
3.6
Carefully tuck all the Wires and Connectors into the
Lower Housing Assembly.
Position the LED Light Fixture Assembly onto the Lower
Housing Assembly, aligning the Three Holes.
NOTE: Verify that the wires and connectors are not
trapped between the LED Light Fixture Assembly
and the Lower Housing Assembly.
Install and tighten the Three #6-32 x 1/4" Truss Head
Screws with Lockwashers (supplied) to complete
the installation of the LED Light Fixture Assembly
(Figure 6).
WARNING
!
To avoid possible fire or shock, do not pinch wires
between the Lower Housing Assembly and the LED
Light Fixture Assembly.
A spare #6-32 x 1/4" Truss Head Screw with
Lockwasher is supplied in the parts bag, if needed.
(Continued)
Figure 5
LOWER HOUSING
ASSEMBLY
Figure 6
Please contact 1-800-777-4440 for further assistance
7
LED LIGHT FIXTURE
ASSEMBLY 2-PIN WIRE
CONNECTOR
FAN 2-PIN WIRE
CONNECTOR
#6-32 x 1/4" TRUSS HEAD SCREWS
WITH LOCKWASHERS (3)
LED LIGHT FIXTURE
ASSEMBLY
luminancebrands.com
ETL Model No.: CF840