Citizen CT-S601 II Manual De Usuario página 59

Ocultar thumbs Ver también para CT-S601 II:
Tabla de contenido
Idiomas disponibles
  • ES

Idiomas disponibles

Switch no.
MSW10-4
Old Command
MSW10-5
Buzzer Event
MSW10-6
Buzzer Sound
MSW13-1
Security/Target
MSW13-5
BT Device Scan
MSW13-6
Auto Reconnect
Note:
*1: If print data is very dense, the print head is hot, data transmission is slow, or some other conditions,
the motor and printing may occasionally stop which causes white stripes in the printout. To print
high-density data, set MSW2-3 (Spool Print) to ON to reduce striping, although this increases the
time before printing starts.
For a serial interface, increase the transmission speed to prevent the motor from stopping.
*2: The values for memory switches MSW7-X are only effective when DIP switch no. 1 is set to OFF .
Function
Initial setting
Invalid
Not by
C.Open
Tone 2
Low/All
Discoverable No Response, Discoverable
Valid
Invalid, CBM1, CBM2
All Event/Error, Not by C.Open, Not by C.Open/PE
Tone 1, Tone 2, Tone 3, Tone 4
Low/All, Mid/All, Mid/Paired only, Hi/All, Hi/Paired
only
Invalid, Valid
— 55 —