WARNING:
Ensure the electricity is turned OFF at the main
switch board before wiring to connector. All work on cable,
pressure chamber and motor should only be carried out by
a qualified Saniflo servicing agent, as special tools are
required.
7
COMMISSIONING THE UNIT
Connect the toilet to the electrical supply. Open the water
supply completely in order to have an efficient rinsing stage.
To activate the flushing cycle, push the button mounted on the
rear edge of the pan. Throw a few toilet paper sheets in the
bowl and start the cycle again.
Wash basin option: turn on the washbasin tap, and the
motor will activate automatically. Check the watertightness of
all connections.
Note:
the basin tap should be watertight. Any dripping will
cause the motor to activate in regular short bursts.
8
USE
SANICOMPACT
/SANICERAMIC
®
special maintenance.
WARNING 1:
The SANICOMPACT
should only be used for the evacuating of normal
human waste, toilet paper and household WC cleansers.
Damage may occur to the machine if the following are
disposed of via the WC; Cotton wool, tampons, sanitary
towels, wet wipes, kitchen towels, condoms as well as
other fabric or hard objects. Solvents, acids and other
chemicals can also cause damage to the unit, and will
invalidate the warranty.
WARNING 2:
In case of a long electrical shut off (vacation,
strike, work being done on the electrical or water supply)
close the water supply.
9
CLEANING AND REMOVAL OF SCALE
• To clean the bowl and remove scale, use regular
bathroom cleaning products.
• To avoid accumulations of scale inside the motor,
we advise you to clean it regularly. To do so:
• Shut off the water supply
• Flush the toilet
• Pour one litre of bathroom cleaning product
(or vinegar) in the bowl
• Leave sit for a few hours
• Open water supply and flush
• the toilet several times.
The frequency of the cleaning depends on the hardness of
the water in your area. We advise you to do it at least once
a year.
Do not put any acids, caustic sodas or solvents down
SANICOMPACT
/SANICERAMIC
®
does not require any
®
/SANICERAMIC
range
®
®
.
®
1 0
REMOVAL
ALL WORK INVOLVING DISMANTLING OF THE APPLIANCE
MUST BE CARRIED OUT BY AN APPROVED REPAIR AGENT
ANY SERVICE WORK INVOLVING ELECTRICAL COMPONENTS SHOULD ONLY BE CARRIED OUT
BY A RECOGNISED SERVICE ENGINEER
1 1
GUARANTIE
The SANICOMPACT
/SANICERAMIC
®
for 2 years, subject to correct installation and usage.
range is guaranteed
®