Setup
3. Setup
AC Power
The Scorpion Dual RGB has an auto-ranging power supply and it can work with an input voltage range of
100 to 240 VAC, 50/60 Hz.
To determine the product's power requirements (circuit breaker, power outlet, and wiring), use the current
value listed on the label affixed to the product's back panel, or refer to the product's specifications chart.
The listed current rating indicates the product's average current draw under normal conditions.
•
Always connect the product to a protected circuit (a circuit breaker or fuse). Make sure
the product has an appropriate electrical ground to avoid the risk of electrocution or
fire.
•
To eliminate unnecessary wear and improve its lifespan, during periods of non-use
completely disconnect the product from power via breaker or by unplugging it.
Never connect the product to a rheostat (variable resistor) or dimmer circuit, even if the
rheostat or dimmer channel serves only as a 0 to 100% switch.
Fuse Replacement
1.
Disconnect the product from power.
2.
Wedge the tip of a flat-head screwdriver into the slot of the fuse holder.
3.
Pry the fuse holder out of the housing.
4.
Remove the blown fuse from the holder and replace with a fuse of the exact same type and rating.
5.
Insert the fuse holder back in place and reconnect power.
Spare fuse holder
(inside safety cap)
Disconnect the product from the power outlet before replacing the fuse.
Always replace a blown fuse with one of the same type and rating.
Power Linking
The product provides power linking via the outlet located in the back of the product. See the diagram below
for further explanation.
Power Linking Diagram
Power
st
1
Source
You can power link up to 27 Scorpion Dual RGB products on 120 VAC or up to 48 Scorpion
Dual RGB products on 230 VAC.
The power linking diagram shown above corresponds to the North American version of
the product ONLY! If using the product in other markets, you must consult with the local
Chauvet distributor as power linking connectors and requirements may differ in your
country or region.
Scorpion Dual RGB User Manual Rev. 3
nd
Product
2
Product
Installed fuse
(held by plastic clip)
Safety cap
Additional
rd
3
Product
Products
Page 7 of 52