INSTALLATION

Installing/Replacing the lamp

Before replacing the lamp, unplug mains lead and let the lamp cool down (approx. 5 minutes).
During the installation do not touch the glass-bulbs bare-handed! Please follow the lamp manufacturer's
notes!
Do not install lamps with a higher wattage! Lamps with a higher wattage generate temperatures the device
was not designed for. Damages caused by non-observance are not subject to warranty.
For the installation, you need one 230 V/100 W G(X)-6.35 lamp.
During the operation, the lamp reaches temperatures of up to 480° C.
Procedure:
Step 1: Unscrew the fixation screws of the service lid on top of the housing.
Step 2: Remove the service lid.
Step 3: If replacing the lamp, remove the old lamp from the lamp-socket.
Step 4: Insert the new 230 V/100 W G(X)-6.35 lamp into the lamp-socket.
Step 5: Replace the service lid and tighten the screws.

STARTING OPERATION

Install the device on a plane surface.
The fluid tank of the device needs to be filled with smoke fluid before starting up operation and always
disconnected from the mains as fluid could be spilled.
Only use quality smoke fluids available at your dealer. We recommend high-quality Eurolite smoke fluids (e.
g. Eurolite Smoke Fluid "P" professional, 5 l). You must not use substances that are classified as "dangerous
working material" or "inflammable fluids".
If fluid should get into the interior of the device, disconnect from mains immediately and consult a technician.
Installation
Install the device in a well-ventilated area. The operation in an unsufficiently ventilated room can lead to a
condensation of the smoke fluid. The resulting slippery surface can cause accidents. Keep a minimum
distance of 20 cm around and above the device.
DANGER TO LIFE!
Only install the lamp with the device switched off!
Unplug from mains before!
CAUTION!
The lamp has to be replaced when it is damaged
or deformed due to the heat!
Do not operate this device with opened service lid!
18/40