Installation

Install the device in a well-ventilated area. The operation in an unsufficiently ventilated room can lead to a
condensation of the smoke fluid. The resulting slippery surface can cause accidents. Keep a minimum
distance of 20 cm around and above the device.
Furthermore do not orientate the escape nozzle directly in the direction of the audience's eyes. In order to
create a good effect, there should be a distance between the device and the audience of at least 1.5 m.
Only install the smoke-machine on scratch resistant and water resistant surfaces.
Please make sure that the inclination angle does not exceed 15°.
This device is only constructed for a standing installation.

Connection with the mains

Connect the device to the mains with the power-plug.
The occupation of the connection-cables is as follows:
Cable
Pin
Brown
Live
Blue
Neutral
Yellow/Green
Earth
The earth has to be connected!

OPERATION

Switch the device on via the power switch. Switch the remote control on via the power ON/OFF switch The
red LED of the remote control lights up.
After a certain warm-up time, the device is ready to operate. The green and red LEDs of the remote control
turn on. By operating the FOG switch on the remote control the smoke emission starts. It may happen that
smoke emission stops. In this case the device is heating up again, and will be ready to operate in approx. 1-
2 min. This process guarantees an appropriate vaporization temperature and the best smoke emission
possible. The temperature is regulated by a high quality thermostat.
Duration
Timer
ON/OFF
Important: Always monitor tank fluid level as you are fogging. Running a fog machine with no fluid can
permanently damage the unit.
If you experience low output, pump noise or no output at all, unplug immediately. Check fluid level, the
external fuse, remote connection, and power from the wall. If all of the above appears to be O.K., plug the
unit in again. If fog does not come out after holding the remote button down for 30 seconds, check the hose
attached to the tank to make sure there is fluid going through the hose. If you are unable to determine the
International
L
N
Intervall
Fog
Power
ON/OFF
15/31
To engage the timer function depress the yellow
TIMER button and adjust the INTERVAL knob. The
INTERVAL knob regulates the length of time of the
smoke blast. The blast can be set for between 10
and 300 seconds. The DURATION knob controls the
amount of smoke. This can be set between 1 and 10
seconds. The green button marked FOG is then
deactivated. To quit the Timer function and to return
to manual mode, depress the yellow Timer button.
The yellow LED turns off.