INSTALLATION INSTRUCTIONS
INSTALLATION TEST (DUCT CHECK)
Once you have completed the installation of the dryer,
use this test to make sure the condition of the exhaust
system is adequate for proper operation of the dryer.
This test should be performed to alert you to any serious
problems in the exhaust system of your home.
The dryer features Check Vent, an innovative sensing system
that automatically detects blockages and restrictions in dryer
ductwork. Keeping ductwork clean of lint buildup and free of
restrictions allows clothes to dry faster and reduces energy
use.
NOTE: The dryer should be cool before starting this test. If the
dryer was warmed up during installation, run the Air Dry cycle
for a few minutes to reduce the interior temperature.
To activate the installation test:
1
Remove the drying rack and literature, then close the
dryer door.
Do not load anything in the drum for this test, as it may
aff ect the accuracy of the results.
2
Press the Power button, then immediately press and
hold both the Temp and Chime buttons until
appears in the display.
3
Press the START/PAUSE button.
The dryer will start the test, which lasts about 2 minutes.
The heat is turned on and the temperatures in the drum
are measured.
INSTALLATION INSTRUCTIONS
4
Check the display for results.
During the test cycle, monitor the CHECK VENT LED on
the control panel. If the LED does not blink by the time the
cycle ends, the exhaust system is adequate. If the exhaust
system is severely restricted, the CHECK VENT LED blinks.
Have the exhaust system checked immediately, as dryer
performance will be poor.
Not blinking:
OK
Other problems may also be shown with error codes.
Refer to the table below for error code details and
solutions.
5
End of cycle.
At the end of the test cycle,
The test cycle ends and the dryer shuts off automatically
after a short delay.
Check any error codes in the chart below before
calling for service.
Error
Possible Causes
Code
tE1
Temperature
or
sensor failure
tE2
Humidity sensor
HS
failure
• Electric dryer
power cord is
not connected
correctly, or
house power
supply is
PS
incorrect.
or PF
or nP
• House fuse is
blown, circuit
breaker has
tripped, or
power outage
has occurred.
19
Blinking:
RESTRICTED
appears in the display.
Solutions
Turn off dryer and call for
service.
Turn off dryer and call for
service.
• Check power supply or
connection of power cord to
terminal block. Refer to the
Connecting Electric Dryers
section of this guide for
complete instructions.
• Reset circuit breaker
or replace fuse. Do not
increase fuse capacity.
If problem is a circuit
overload, have it corrected
by a qualifi ed electrician.