Since the built-in micro computer takes about 3
seconds to confirm that the battery being charged
with UC24YF is taken out, wait for a minimum of
3 seconds before reinserting it to continue charging.
If the battery is reinserted within 3 seconds, the
battery may not be properly charged.

MAINTENANCE AND INSPECTION

1. Inspecting the mounting screws:
Regularly inspect all mounting screws and ensure
that they are properly tightened. Should any of the
screws be loose, retighten them immediately. Failure
to do so could result in serious hazard.
2. Cleaning of the charger
When the charger is stained, wipe with a soft dry
cloth or a cloth moistened with soapy water. Do
not use chloric solvents, gasoline or paint thinner,
for they melt plastics.
3. Store idle charger
When not in use, the charger should be stored in
dry, high or locked-up place — out of reach of
children.
NOTE
Due to HITACHI's continuing program of research and
development, the specifications herein are subject to
change without prior notice.
IMPORTANT
Correct connecting of the plug
The wires of the mains lead are coloured in accordance
with the following code:
Blue:
–Neutral
Brown: –Live
As the colours of the wires in the mains lead of this tool
may not correspond with the coloured markings
identifying the terminals in your plug proceed as follows:
The wire coloured blue must be connected to the terminal
marked with the letter N or coloured black.
The wire coloured brown must be connected to the
terminal marked with the letter L or coloured red.
Neither core must be connected to the earth terminal.
NOTE
This requirement is provided according to BRITISH
STANDARD 2769: 1984.
Therefore, the letter code and colour code may not be
applicable to other markets except United Kingdom.