Second Section - FOR THE INSTALLER
During installation, carry-out a good machine levelling, which is a prerequisite for a correct
operation thereof.
The Manufacturer cannot assume any responsability for any damage to persons or
property deriving from the non-observance of the above-specified norms.
ELECTRICAL CONNECTION
WARNING!
to live components!
During all electric operation, disconnect the machine
from the network and verify the absence of
power.
The machine and its accessories must be connected
in accordance with local regulations, by a
Company specialized in electrical installations
and authorized by competent
Before connecting the machine,
check to make sure the voltage
outlet of the mains is
the same as the voltage specified
on the data plate of the machine.
A main switch must be installed between
the mains and the machine. This safety
measure
also requires that the minimum
distance between the switch contacts is at
least 3 mm and the
disconnection on all poles according to EN
60204 (VDE 113).
Fuses on the main switch must be 16 A .
The mains must be wired to be able to
handle the current drawn by the machine.
The system must also be provided with a
proper ground lead in accordance with the
existings norms. The electric
cable must be of the following
type H07RN-F.
:
: Danger to life due
authorities.
For the right choice of the cross section
area refer to the following table:
Cross Section area
mm²
0,75
1
1,5
2,5
The electrical safety of this equipment is
only assured if it is connected as follows.
It is necessary to connect the equipment to
an effective ground installation, as specified
by the
electrical safety regulations in force.
Chack that this basic requirement is
complied with and, in case of doubt, ask for
a careful check of
the installation by a qualified personal.
In addition, the equipment shall be part of
an equipotential system, the effectiveness
of which
should
be
checked
regulations in force.
The connection should be made at the
screw marked by the respective label
located on the
equipment back side (
THE MACHINE SHALL BE CONNECTED
WITH AN EFFECTIVE GROUND CLAMP.
The manufacturer declines any responsibility
for any damages caused by lack of an
effective
ground installation.
ENGLISH
Total loading
A
< 6
6 ÷ 10
10 ÷ 16
16 ÷ 25
according
to
the
).
loading