V2 AYROS-24V Serie Manual De Instrucciones página 51

Tabla de contenido
Idiomas disponibles

Idiomas disponibles

PARAMETER
VALUE
Pot
30 - 100
P.rAL
0 - 70
Po.AL
0 - 70
SPUn
no
Si
rAM
6 - 0
SEnS
no
1.0A-16.0A
rA.AP
0 - 100
rA.Ch
0 - 100
St.AP
PAUS
ChiU
no
St.Ch
StoP
APEr
DESCRIPTION
Motor power
The displayed value is the percentage of max. motor power
Power motor during slow-down phase
The value displayed represents the percentage of the maximum motor
power
Power used for the realignment on the limit
Power used in searching for the position of the limit, in self-learning
phases or after reset
Start off
If this function is activated, for the first 2 seconds of motion of each door,
Pot
the control unit will ignore
power command in order to overcome the gate inertia
Function deactivated
Function activated
Starting ramp
In order not to stress too much the motor, when the motion starts the
power is gradually increased, until reached the set value or 100% if the
take-off is enabled.
Higher is the set value, longer the length of time of the ramp, that is the
time necessary to reach the value of nominal power.
Adjusting the obstacle sensor
Function deactivated
This menu allows adjustment of the sensitivity of the obstacle sensor.
When the current absorbed by the motor exceeds the value set, the
control unit detects an alarm
Slow down in opening
This menu allows regulating the percentage of the ride/drive that is carried
out at reduced speed during the last opening stretch
Slow down in closing
This menu allows regulating the percentage of the ride/drive that is carried
out at reduced speed during the last closing stretch
Start command during the opening phase
This menu allows fixing the control unit conduct in case it receives a Start
command during the opening phase
The gate stops and goes to pause
The gate immediately starts closing
The gate go on with the opening phase (command is ignored)
Start command during the closing phase
This menu allows fixing the control unit conduct in case it receives a Start
command during the closing phase
The gate stops and its cycle is considered as finished
The gate opens again
value and it will give motor the maximum
- 49 -
DEFAULT
MEMO
60
(STD)
100
(FAST)
20
30
(STD)
25
(FAST)
no
1
(STD)
3
(FAST)
no
20
(STD)
25
(FAST)
20
(STD)
25
(FAST)
PAUS
StoP
Tabla de contenido
loading

Tabla de contenido