Kruger 140 Instrucciones Para El Uso página 15

Tabla de contenido
Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 28
3
WALL MOUNTING
- Position the template (14) on the desired wall to
mount the equipment. Mounting it at a height of no
less than 1,6 meters (approx. 63 inches) is advised.
Check the position of the holes to be made, making
sure that they are correctly aligned (fig.2).
- Tighten the shaft (15) with the four screws (16)
provided. (fig. 3).
- Position the machine on the fixed staff and register
the position of the other two holes to be made by
the lower part of the machine (Fig. 4).
- Once the holes are made, position the assembled
machine and attach it permanently (17 -fig.15 and
20 – 21 – fig.4).
WARNING! Attach the machine on a wall
that can sustain the weight of approximately
30 Kg. (66 Lbs.)
- Insert the staff to the accessory door (18) and attach
with the appropriate screws (22 – fig. 6)
- Insert the handle (19) for the tube cover and attach
with the self tapping screw furnished (fig.7)
4
CONNECTION OF THE WATER SUPPLY
PIPE
Connect a clean water supply pipe to the
water mains, checking to ensure that the
minimum pressure is of 1.5 bar and maxi-
mum is of 6 bar, with a minimum flow rate
of 7 l per min.
- Remove the cap for water to enter (fig. 8).
- Connect the water supply pipe (min. diam ½") to
the water mains (fig.9)
- Fit the click-on attachment (Fig. 10 - pos.1) onto
the fitting (2);
5
HIGH PRESSURE PIPE CONNECTION
- Unwind the high pressure tube from the tube cove-
ring kit.
- Twist the high pressure tube on the gun ( fig. 11).
Assembly of the detergent spraying device
(Fig. 6)
- Insert the adaptor in the gun, rotate by 90º and,
extracting it, engage the trigger mechanism (fig.
12A).
- Insert the nozzle and tighten the locknut of the
adaptor (fig. 12B).
6
ELECTRICAL CONNECTION OF THE
APPLIANCE
The mains voltage must match the operating voltage.
(See identification plate)
- Insert the plug into a power socket installed in
compliance with regulations.
Check the minimum section of the individual cables
using extensions.
Position the extensions so as to maintain the protection
class of the equipment.
Voltage
Cable
V
length m
230
up to 2
230
20 to 5
7
APPLIANCE ACTIVATION
Use the machine only after installing it on a
wall and after connecting the water feeding
tube and turning on the faucet.
- Turn the switch, located on the front of the machine
to ON (Fig. 13).
- Position the spray gun on the object to be
cleaned - never on people !
- Press the safety device (Fig. 14 - pos. 1) - the gun
is released
- Direct the nozzle downwards
- Fully press down the trigger (Fig. 14 - pos.2)
15
Cross-section
mm
2
1,5
2,5
Tabla de contenido
loading

Este manual también es adecuado para:

160Modular 140Modular 160

Tabla de contenido