Haier H21BFC45N Manual Del Usuario página 32

Tabla de contenido
Idiomas disponibles

Idiomas disponibles

English
Problem
Automatic icemaker
The
icemaker
has stopped
making ice.
The ice
making
capacity is
low.
The
icemaker
runs
continuously.
31
Cause
• The ice cube height sensor
arm has detected a full
tray condition.
• The water supply valve is
closed.
• The freezer section is not
cold enough.
• The water source saddle
valve is somehow blocked.
• The freezer drawer area is
not cold enough.
• The water supply valve
does not have enough
pressure or does not open
all the way.
• The icemaker sensor arm
is restricted or out of
position.
• The icemaker level sensor
is stuck in the down
position.
Solution
• To make more ice cubes you
may need to distribute your ice
to the center drawer right side
(or lower drawer) to increase
ice cube harvest volume.
• Turn on the water supply valve.
• Adjust the setting in the freezer
to a colder setting and allow it
to balance within 24 hours.
• Check the water supply
saddles valve for obstruction
and replace it if damaged.
• Set the freezer drawer to a
colder setting.
• Make sure the water pressure
is between 25-121 psi and
add water booster if too low.
• Make sure the water valve
supply is open all the way.
• Make sure the water filter is
distributing enough water and
is not clogged.
• Make sure the drawer gaskets
are sealing and kept clean
from dirt and debris.
• Check the movement of the
icemaker sensor arm so it rests
in the "up" position.
• Make sure no frozen packs or
objects are obstructing the
icemaker sensor arm.
Tabla de contenido