General data
Electrical isolation
Surge protection
Air and creepage distances between the circuits
Rated voltage
Rated surge voltage
Pollution degree
Surge voltage category
Mounting position
Housing material
Dimensions (W/H/D)
Conductor cross-section
Safety characteristic data
Category
Performance level
SILCL
Safety Integrity Level (SIL)
Parameters
MTTF
D
DC
Parameters
as per IEC 61508 (EN 62061)
PFH
Proof test interval (T
1
1)
No capacitive load must be taken into account when using electromechanical components
(e.g. contactors).
2)
A suitable and effective protective circuit is to be provided for inductive loads.
One recommended measure is the use of free-wheeling diodes.
3)
Specifications are applicable only if the safety function is requested at least once a year.
4)
Since all diagnostics tests are carried out during operation, the service life for the proof test interval
is adopted.
Derating curve:
screw connection
spring-cage connection
screw connection
spring-cage connection
as per EN 954-1
as per EN ISO 13849-1
as per EN 62061
as per IEC 61508
as per EN ISO 13849
)
[months]
2
1,5
1
0,5
0
0
25 30 35 40 45 50 55 60
Yes, between power supply for logic
(A1/A2) and power supply for safe outputs
(24 V/0 V)
Suppressor diode
As per DIN EN 50178:1998-04 1
basic insulation
50 V
0.8 kV
2
III
Horizontal
Polyamide PA, non-reinforced
(67.5/114.5/ 99) mm
(67.5/114.5/112) mm
0.2 - 2.5 mm
0.2 - 1.5 mm
4
e
3
3
3)
[years]
8321 (high)
99 % (high)
3)
-8
[1/h]
1.37 x 10
4)
240
Ambient temperature [°C]
2
(AWG 24-12)
2
(AWG 24-16)
23