CONTROL BOX CONFIGURATION
POINT
DESCRIPTION
1
M1, terminals:1,2,3
2
M2, terminals:4,5,6
Terminals:7,8,9
3
M3, terminals:10,11
Terminals:12,13
Terminals:13,14
4
M4, terminals:15,16
Terminals:17,20
Terminals:18,20
Terminals:19,20
5
M5,terminals:21,24
Terminals:22,24
Terminals:23,24
Terminals:25,26
Terminals:27,28
6
CN1/CN2, connector
7
CH1, pushbutton
8
CH2, pushbutton
9
L1, pushbutton
10
JMP1, jumper
11
DIP1
12
PT4, potentiometer
13
PT3, potentiometer
14
PT2, potentiometer
15
PT1, potentiometer
FUNCTION
Feeder cable
Drive 1 (master)
Drive 2 (second)
no function
no function
Flashing lamp
Connection for accessories 24V
Impulse transmitter channel 1
Impulse transmitter channel 2
Emergency-stop push-button /
must be bridged without switch
connected
photocell active OPEN
photocell active CLOSED
photocell active OPEN +
CLOSED
Contact strip 8.2 kilo ohms
Antenna
Radio module sockets
Learn/Delete radio channel 1
Learn/Delete radio channel 2
Learning the distance covered
Programming the photocell
Dip switch block
Force setting drive 2
Force setting drive 1
Automatic closing
Bipart delay
DESCRIPTION OF THE LEDs
RED LEDs should be switched off. Indication of faults to be
rectified; this does not apply to failsafe photocells not connected.
(see "JUMPER" description)
(Example: short circuit, photocells and/or contact strip)
POINT
DESCRIPTION
LED A
RED Learn/Delete radio channel 1
LED B
RED Start impulse channel 1
LED C
RED Learn/Delete radio channel 2
LED D
RED Start impulse channel 2
LED E
RED photocell active for OPEN
LED F
RED photocell active for CLOSE
LED G
RED photocell active for OPEN/CLOSE
LED H
RED contact strip
LED I
GREEN stop
LED J
RED learn program (distance covered)