Idiomas disponibles

Idiomas disponibles

Enlaces rápidos

BRUCIATORI DI OLIO DENSO / HEAVY OIL BURNERS
BRULEURS A FIOUL LOURD/QUEMADORES DE FUEL PESADO
OILFLAM
OILFLAM D 300.1 PR/MD
OILFLAM
OILFLAM D 400.1 PR/MD
AIR DAMPER MOTOR
230 / 400 V 50 Hz
300.1 PR/MD
400.1 PR/MD
LB 1434
28.11.2005
Tabla de contenido
loading

Resumen de contenidos para Ecoflam OILFLAM300.1 PR/MD

  • Página 1 BRUCIATORI DI OLIO DENSO / HEAVY OIL BURNERS BRULEURS A FIOUL LOURD/QUEMADORES DE FUEL PESADO OILFLAM 300.1 PR/MD OILFLAM D 300.1 PR/MD OILFLAM 400.1 PR/MD OILFLAM D 400.1 PR/MD AIR DAMPER MOTOR 230 / 400 V 50 Hz LB 1434 28.11.2005...
  • Página 2 ABCD LB1434 Oilflam 300.1-400.1 PR/MD CARATTERISTICHE TECNICHE / TECHNICAL DATA CARACTERISTIQUES TECHNIQUES / CARACTERISTICAS TECNICAS Modello / Models / Modeles / Modelos OILFLAM 300.1 PR OILFLAM 400.1 PR Portata termica max. / Thermal power max. kcal/h 2.586.000 3.362.000 Puissance thérmique max./ Potencia térmica máx. 3.000 3.900 Portata termica min.
  • Página 3 ABCD LB1434 Oilflam 300.1-400.1 PR/MD DIMENSIONI D’INGOMBRO / OVERALL DIMENSIONS DIMENSIONS D'ENCOMBREMENT / DIMENSIONES GLOBALES (mm) D (D1) MODELLO MODELS MODELES MODELOS OILFLAM 300.1 1131 OILFLAM 400.1 1131 D = testa corta / short head / tête courte / cabeza corta D1 = testa lunga / long head / tête longue / cabeza larga MONTAGGIO BRUCIATORE / BURNER INSTALLATION INSTALLATION DU BRULEUR / INSTALACIÓN DEL QUEMADOR 1 - Bruciatore / Burner / Brûleur / Quemador...
  • Página 4 ABCD LB1434 Oilflam 300.1-400.1 PR/MD ALIMENTAZIONE OLIO COMBUSTIBILE / HEAVY OIL FEEDING ALIMENTATION DU FIOUL LOURD / ALIMENTACIÓN FUEL PESADO 230V 50Hz 1 - Aspirazione / Suction / Aspiration / Aspiración 5 - Regolazione pressione / Pressure adjustment 2 - Ritorno / Return / Retour / Retorno Régulation pression / Regulación presión 3 - Sfiato e presa manometro / Bleed and pressure gauge port 6 - All’ugello / Nozzle outlet / Au gicleur / Al inyector...
  • Página 5 ABCD LB1434 Oilflam 300.1-400.1 PR/MD DIAGRAMMA PRESSIONE POMPA / TEMPERATURA OLIO PUMP’S PRESSURE / OIL TEMPERATURE DIAGRAM DIAGRAMME PRESSION POMPE / TEMPERATURE FIOUL DIAGRAMA PRESIÓN DE LA BOMBA / TEMPERATURA COMBUSTIBLE La gasificazione di frazioni volatili contenute nell’olio combustibile riscaldato, risulta essere la causa principale dell’usura prematura della pompa di alimentazione.
  • Página 6 ABCD LB1434 Oilflam 300.1-400.1 PR/MD SCHEMA ALIMENTAZIONE COMBUSTIBILE / HEAVY OIL FEED SYSTEM SCHEMA ALIMENTATION DU FIOUL LOURD / ESQUEMA ALIMENTACIÓN FUEL PESADO Schema per olio combustibile fluido fino a 50°E a 50°C / Drawing for fluid fuel oil up to 50°E at 50°C 1 - Bruciatore/Burner/Brûleur/Quemador 2 - Serbatoio/Tank/Réservoir/Tanque 3 - Riscaldatore/Heater...
  • Página 7: Comprobaciones A Efectuar Para Una Correcta Instalación

    ABCD LB1434 Oilflam 300.1-400.1 PR/MD VERIFICHE DA EFFETTUARE AI FINI DI UNA CORRETTA INSTALLAZIONE: Prima di procedere al riempimento del circuito di alimentazione e successiva messa in funzione dell’impianto, è consigliabile effettuare i controlli seguenti: - La linea di alimentazione deve essere adeguata al carico assorbito dall’impianto - I fusibili devono essere adeguati al carico dall’impianto - I termostati caldaia devono essere stati collegati correttamente - Tensione e frequenza devono essere comprese nei limiti specificati...
  • Página 8 ABCD LB1434 Oilflam 300.1-400.1 PR/MD PRIMA DI PROCEDERE CON IL RIEMPIMENTO DEL CIRCUITO NAFTA EFFETTUARE I SEGUENTI CONTROLLI: - Controllare il senso di rotazione del motore (nella versione trifase) - Verificare che vi sia combustibile nel serbatoio - I rubinetti delle tubazioni devono essere aperti - La tubazione di ritorno del combustibile deve essere libera da occlusioni Dopo aver effettuato i suddetti controlli, procedere nel modo seguente: - Inserire un manometro di controllo pressione del combustibile...
  • Página 9: Antes De Efectuar El Relleno Del Circuito Del Combustible Comprobar Los Lo Que Sigue

    ABCD LB1434 Oilflam 300.1-400.1 PR/MD - Réconnecter le câble d’alimentation des résistances - Reporter le valeur initiale de OUT1 - OUT1 - OUT3 - OUT 4 dans le regulateur GEFRAN - Brancher de nouveau le coffret de sécurité ANTES DE EFECTUAR EL RELLENO DEL CIRCUITO DEL COMBUSTIBLE COMPROBAR LOS LO QUE SIGUE: - Comprobar el sentido de rotación del motor - Que hay combustible en el tanque...
  • Página 10 ABCD LB1434 Oilflam 300.1-400.1 PR/MD MODULATING OPERATION With the bumer in the start position and the appliance thermostats enabled, power is delivered to the resistances (G) of the preheater and heating cartridges for the pumps and the fuel supply line to the head (O). When the preheater thermostat reaches the set value, (usually a minimum of about 90°C is necessary to guarantee a good level of circulation) the pump start-up is enabled (set point on out 1, if using the GEFRAN 200 thermoregulating device).
  • Página 11 ABCD LB1434 Oilflam 300.1-400.1 PR/MD FLUIDICS NOZZLE - pag.11 -...
  • Página 12 ABCD LB1434 Oilflam 300.1-400.1 PR/MD - pag.12 -...
  • Página 13 ABCD LB1434 Oilflam 300.1-400.1 PR/MD REGOLAZIONE DELLA PORTATA D'ARIA DI COMBUSTIONE (LANDIS SQM 50.481A2) LANDIS & GYR SQM 50.481A2 AIR DAMPER SERVOMOTOR ADJUSTMENT REGULATION SERVOMOTEUR DU CLAPET DE L’AIR LANDIS & GYR SQM 50.481A2 REGULACIÓN SERVOMOTOR DEL CIERRE DEL AIRE LANDIS & GYR SQM 50.481A2 OILFLAM 300.1-400.1 PR Togliere il coperchio per accedere alle camme di regolazione.
  • Página 14 ABCD LB1434 Oilflam 300.1-400.1 PR/MD REGOLAZIONE TEMPERATURE OLIO COMBUSTIBILE ADJUSTMENT OF FUEL TEMPERATURE Display Decrease key Pulsante diminuzione Increase key Pulsante aumento “Function” key Pulsante “Funzione” F AIl display mostra la temperatura dell'olio. Le 4 spie luminose sono collegate alle seguenti funzioni : Out 1 :contatto che guida le resistenze di lavoro Out 2 :contatto che che guida le resistenze superiori KMRL1 Out 3: contatto che guida le resistenze superiori KMRL2...
  • Página 15 ABCD LB1434 Oilflam 300.1-400.1 PR/MD - if You need to modify an other temperature press again “F” untill You the relevant led flashes. Please take care: if key “F” is pressed for a too long time, You enter in “configuration level” phase1, (see “CF1”...
  • Página 16 ABCD LB1434 Oilflam 300.1-400.1 PR/MD POSIZIONE ELETTRODI DI ACCENSIONE POSITION OF IGNITION ELECTRODES Per una corretta accensione del bruciatore le quote riportate nel disegno devono essere rispettate. For a correct burner ignition, carefully respect the dimensions shown by the picture Pour un allumage correct du brûleur, veiller à...
  • Página 17 ABCD LB1434 Oilflam 300.1-400.1 PR/MD REGOLATORE A MICROPROCESSORE RWF 40 Significato del display e dei tasti del regolatore a microprocessore RWF 40 Nella figura viene visualizzato il display di base, Display: che indica il valore reale ed il setpoint ingresso analogico impostato, é...
  • Página 18: Impostazioni Parametri

    ABCD LB1434 Oilflam 300.1-400.1 PR/MD IMPOSTAZIONI PARAMETRI All’accensione del bruciatore tutti i dislay del regolatore sono accesi, il display del setpoint lampeggerà per circa 10 sec. Il valore visualizzato nel dislay superiore (rosso) indica il valore reale. Il valore visualizzato nel dislay inferiore (verde) indica il valore del setpoint impostato.
  • Página 19 ABCD LB1434 Oilflam 300.1-400.1 PR/MD PARAMETRIZZAZIONE 17.5 12.5 -2.5 -7.5 -12.5 -17.5 Temperatura esterna (°C) SCHEMI COLLEGAMENTO SONDE Collegamento sonda Cod. S721 Cod. RWF 40 Cod. QAE2..(sonda passiva) S720/1 S731 Sonda acqua S731/1 Codice configurazione S731/2 C111 = 9XXX 1 2 3 4 S731/3 S731/4 OBE620-P..
  • Página 20 ABCD LB1434 Oilflam 300.1-400.1 PR/MD INDICAZIONI CONFIGURAZIONE INGRESSI C111 - C112 Ingresso analogico 1 (valore reale) Ingresso analogico 3 (temperatura esterna) Pt1000, 2 fili, Landis & Staefa IEC 751 Nessuna funzione (sonda non attiva) FT-TP/...(sonda passiva) Sonda esterna Pt 1000, 2 fili, Ni1000, 2 fili, Landis &...
  • Página 21 ABCD LB1434 Oilflam 300.1-400.1 PR/MD NEL CASO DI NECESSITÀ DI SOSTITUZIONE PROCEDERE COME INDICATO NELLE SOTTOSTANTI FIGURE A-B-C Inserire il regolatore RWF 40 nell’apposita apertura del cassetto elettrico (A). Inserire nelle fessure i tasselli ad incastro con le viti, quindi bloccarla al pannello della cassetta per una corretta tenuta (B).
  • Página 22 ABCD LB1434 Oilflam 300.1-400.1 PR/MD IMPOSTAZIONI PARAMETRI Parametro Display Valore impostato Valore impostato Valore impostato (sonda passiva) (sonda passiva) (sonda attiva) QAE22 FT-TP/1000 QBE620-P... Valore limite del contatto ausiliario Differenziale di commutazione del contatto ausiliario HYSt Banda proporzionale Pb.1 Tempo dell’azione derivata Tempo dell’azione integrale Banda morta Tempo di corsa del servocomando (sec.)
  • Página 23 ABCD LB1434 Oilflam 300.1-400.1 PR/MD RWF 40 MICROPROCESSOR REGULATOR Description of display and keys on the RWF 40 microprocessor regulator The figure shows the normal display indicating Display: the actual value and the programmed set analog input 1 point, and equally important, (actual value) gives the meaning of the single keys and indicator Leds.
  • Página 24: Setting Parameters

    ABCD LB1434 Oilflam 300.1-400.1 PR/MD SETTING PARAMETERS When the burner is ignited all displays of the regulator light up. The set point display will blink for about 10 seconds. The value in the upper field of the display (red) indicates the actual value. The value in the lower field of the display (green) indicates the set point currently programmed.
  • Página 25 ABCD LB1434 Oilflam 300.1-400.1 PR/MD PARAMETERIZATION 17.5 12.5 -2.5 -7.5 -12.5 -17.5 External temperature (iC) PROBE CONNECTION DIAGRAMS Connection for probe Cod. S721 Cod. RWF 40 Cod. QAE2..(passive probe) S720/1 S731 Water probe S731/1 Configuration code S731/2 C111 = 9XXX 1 2 3 4 S731/3 S731/4...
  • Página 26 ABCD LB1434 Oilflam 300.1-400.1 PR/MD C111 – C112 INPUT CONFIGURATION INDICATIONS Analog input 1 (actual value) Analog Input 3 (external temperature) Pt1000, 2-wire, Landis & Staefa IEC 751 No function (probe not active) FT-TP/… (passive probe) External probe Pt 1000, 2-wire, QAC22 (passive probe) Ni1000, 2-wire, Landis &...
  • Página 27 ABCD LB1434 Oilflam 300.1-400.1 PR/MD WHEN REPLACEMENT IS NECESSARY, PROCEED AS SHOWN IN FIGURES A-B-C BELOW Insert the RWF 40 regulator through the relative opening in the electrical panel (A). Insert the fixing anchors and screws into the slots, and secure the unit to the panel (B). To open the regulator, squeeze the cover from the ends as shown, and lift out (C).
  • Página 28: Configuration

    ABCD LB1434 Oilflam 300.1-400.1 PR/MD PARAMETERS Parameter Display Ecoflam setting Ecoflam setting Ecoflam setting (passive probe) (passive probe) (active probe) QAE22 FT-TP/1000 QBE620-P... Limit value of limit comparator Switching differential for limit comparator HYSt Proportional band Pb.1 Derivative time Integral action time Dead band (neutral zone) Actuator running time (sec.)
  • Página 29 ABCD LB1434 Oilflam 300.1-400.1 PR/MD REGULATEUR COMPACT UNIVERSEL RWF40 Déscription de l’affichage à cristaux liquides (display) et des touches du regulateur RWF40 Affichage à cristaux liquides: Entrée analogique 1 (valeur réelle) Affichage à cristaux liquides: consigne SP1 Signal commande manuelle Signal de commande «...
  • Página 30: Fonctionnement Manuel/Automatique

    ABCD LB1434 Oilflam 300.1-400.1 PR/MD INTRODUCTION DES PARAMETRES A l’allumage du brûleur tous les LED sur la façade sont allumés. L’ affichage à cristaux liquides (display) du consigne clignotera pour environ 10sec. L’affichage à cristaux liquides supérieur (rouge) indique la valeur mesurée et pendant le reglage, il indique les paramètres entrés;...
  • Página 31 ABCD LB1434 Oilflam 300.1-400.1 PR/MD PARAMETRISATION 17.5 12.5 -2.5 -7.5 -12.5 -17.5 température éxtérieure (°C) Schéma de branchement avec les sondes Branchement sonde Cod. S721 Cod. RWF 40 Cod. QAE2..(sonde passive) S720/1 S731 Sonde eau S731/1 Code C111 = 9XXX S731/2 1 2 3 4 S731/3...
  • Página 32 ABCD LB1434 Oilflam 300.1-400.1 PR/MD INDICATION DE CONFIGURATION ENTREES C111-C112 Entrée analogique 1 (valeur réelle) Entrée analogique 3 (température éxtérieure) Pt1000, 2 fils, Landis & Staefa IEC 751 Aucune fonction (sonde non active) FT-TP/...(sonde passive ) Sonde éxtérieure Pt 1000, 2 fils, Ni1000, 2 fils, Landis &...
  • Página 33 ABCD LB1434 Oilflam 300.1-400.1 PR/MD SUBSTITUTION DU REGULATEUR Les déscriptions A,B,C indiquent comme l’on doit démonter et remonter le régulateur RWF40. C – Pour enlever le régulateur, exercer une pression sur le couvercle et enléver le même. A – Introduire le régulateur RWF40 dans l’ouverture B –...
  • Página 34 ABCD LB1434 Oilflam 300.1-400.1 PR/MD PARAMETRES Parametro Display Valore impostato Valore impostato Valore impostato (sonda passiva) (sonda passiva) (sonda attiva) QAE22 FT-TP/1000 QBE620-P... Valore limite del contatto ausiliario Differenziale di commutazione del contatto ausiliario HYSt Banda proporzionale Pb.1 Tempo dell’azione derivata Tempo dell’azione integrale Banda morta Tempo di corsa del servocomando (sec.)
  • Página 35: Controlador Microprocesador Rwf

    ABCD LB1434 Oilflam 300.1-400.1 PR/MD CONTROLADOR MICROPROCESADOR RWF 40 Significado del display y de los botones del controlador microprocesador RWF 40 La pantalla del RWF40... muestra los valores y símbolos de una situación tras ser conectado. Esta situación es la del display Display valor real básico.
  • Página 36: Manejo De Los Parametros

    ABCD LB1434 Oilflam 300.1-400.1 PR/MD MANEJO DE LOS PARAMETROS En el encendido del quemador todos los displays están iluminados, el display de la consigna parpadea durante unos 10segundos tras su conexión. El valor real aparece en el display de valor real (rojo). La consigna aparece en el display de consigna (verde). CAMBIO CONSIGNA Para modificar las consignas hay que proceder como sigue: - - Con el tras...
  • Página 37: Esquema De Conexion Sonda

    ABCD LB1434 Oilflam 300.1-400.1 PR/MD Parametrización 12.5 -2.5 -7.5 -12.5 -17.5 17.5 Temperatura exterior (°C) ESQUEMA DE CONEXION SONDA Conexión sonda Cod. S721 Cod. RWF 40 Cod. QAE2..(sonda pasiva) S720/1 S731 Sonda agua S731/1 Código de configuración S731/2 C111 = 9XXX 1 2 3 4 S731/3 S731/4...
  • Página 38: Señalización Averías / Anomalias Los Numeros Parpadean En El Display

    ABCD LB1434 Oilflam 300.1-400.1 PR/MD CONFIGURACION ENTRADAS C111 - C112 Entrada analógica 1 (valor real) Entrada analógica 3 (temperatura exterior) Pt1000, 2 hilos, Landis & Staefa IEC 751 Ninguna función (sonda no activa) FT-TP/...(sonda pasiva) Sonda exterior Pt 1000, 2 hilos, Ni1000, 2 hilos, Landis &...
  • Página 39 ABCD LB1434 Oilflam 300.1-400.1 PR/MD EN CASO DE NECESIDAD DI SUSTITUCIÓN PROCEDER COMO ESTA INDICADO EN LAS FIGURAS SUBRAYADAS A-B-C Insertar frontalmente el controlador en el cuadro. (A). En la parte posterior del cuadro, acoplar los elementos de fijación en las ranuras laterales o superiores.
  • Página 40: Imposicion De Parametros

    ABCD LB1434 Oilflam 300.1-400.1 PR/MD IMPOSICION DE PARAMETROS Parametro Display Valor impuesto Valor impuesto Valor impuesto (sonda pasiva) (sonda pasiva) (sonda activa) QAE22 FT-TP/1000 QBE620-P... Valor limite del contacto auxiliar Diferencial de conmutación del contacto auxiliar HYSt Banda proporcional Pb.1 Tiempo del la accion derivada Tiempo de la accion integral Banda muerta...
  • Página 41 ABCD LB1434 Oilflam 300.1-400.1 PR/MD - pag.41 -...
  • Página 42 ABCD LB1434 Oilflam 300.1-400.1 PR/MD - pag.42 -...
  • Página 43 ABCD LB1434 Oilflam 300.1-400.1 PR/MD - pag.43 -...
  • Página 44 ABCD LB1434 Oilflam 300.1-400.1 PR/MD - pag.44 -...
  • Página 45 ABCD LB1434 Oilflam 300.1-400.1 PR/MD - pag.45 -...
  • Página 46 ABCD LB1434 Oilflam 300.1-400.1 PR/MD - pag.46 -...
  • Página 47 ABCD LB1434 Oilflam 300.1-400.1 PR/MD - pag.47 -...
  • Página 48 ABCD LB1434 Oilflam 300.1-400.1 PR/MD OILFLAM 300.1 PR OILFLAM 400.1 PR DESCRIZIONE N° codice codice 1 - POMPA SUNTEC E 7NC 1069P P104 SUNTEC TA3C40106 P148/1 P148/1 2 - RESISTENZA POMPA 50 W R110 R110 3 - FLESSIBILI 25 x1500 S901/2 S901/2 4 - BOBINA...
  • Página 49 ABCD LB1434 Oilflam 300.1-400.1 PR/MD OILFLAM 300.1 PR OILFLAM 400.1 PR DESCRIZIONE N° codice codice 49 - BOCCAGLIO BFB07029/103 BFB07028/103 BFB07029/203 BFB07028/203 50 - CAMPANA INOX BFB07029/3 BFB07028/3 51 - ASSIEME TESTA DI COMBUSTIONE 52 - GUARNIZIONE BFG04056/1 BFG04056/1 53 - GUARNIZIONE BFG04057/1 BFG04057/2 54 - GUARNIZIONE...
  • Página 50 ABCD LB1434 Oilflam 300.1-400.1 PR/MD OILFLAM 300.1 PR OILFLAM 400.1 PR DESCRIPTION N° code code 1 - PUMP SUNTEC E 7NC 1069P P104 SUNTEC TA3C40106 P148/1 P148/1 2 - HEATING ELEMENT PUMP 50 W R110 R110 3 - HOSES 25 x1500 S901/2 S901/2 4 - COIL...
  • Página 51 ABCD LB1434 Oilflam 300.1-400.1 PR/MD OILFLAM 300.1 AB OILFLAM 400.1 PR DESCRIPTION N° code code 49 - BLAST TUBE BFB07029/103 BFB07028/103 BFB07029/203 BFB07028/203 50 - BLAST TUBE END BFB07029/3 BFB07028/3 51 - ASSEMBLY FIRING HEAD 52 - GASKET BFG04056/1 BFG04056/1 53 - GASKET BFG04057/1 BFG04057/2...
  • Página 52 ABCD LB1434 Oilflam 300.1-400.1 PR/MD OILFLAM 300.1 PR OILFLAM 400.1 PR DESIGNATION N° code code 1 - POMPE SUNTEC E 7NC 1069P P104 SUNTEC TA3C40106 P148/1 P148/1 2 - RESISTANCES 50 W R110 R110 3 - FLEXIBLES 25 x1500 S901/2 S901/2 4 - VANNE EL011...
  • Página 53 ABCD LB1434 Oilflam 300.1-400.1 PR/MD OILFLAM 300.1 PR OILFLAM 400.1 PR DESIGNATION N° code code 49 - GUEULARD BFB07029/103 BFB07028/103 BFB07029/203 BFB07028/203 50 - TERMINAL INOX BFB07029/3 BFB07028/3 51 - GROUPE TETE DE COMBUSTION 52 - JOINT BFG04056/1 BFG04056/1 53 - JOINT BFG04057/1 BFG04057/2 54 - JOINT...
  • Página 54 ABCD LB1434 Oilflam 300.1-400.1 PR/MD OILFLAM 300.1 PR OILFLAM 400.1 PR DESCRIPCIÓN N° código código 1 - BOMBA SUNTEC E 7NC 1069P P104 SUNTEC TA3C40106 P148/1 P148/1 2 - RESISTENCIA BOMBA 50 W R110 R110 3 - LATIGUILLOS 25 x1500 S901/2 S901/2 4 - BOBINA...
  • Página 55 ABCD LB1434 Oilflam 300.1-400.1 PR/MD OILFLAM 300.1 PR OILFLAM 400.1 PR DESCRIPCIÓN N° código código 49 - TUBO LLAMA BFB07029/103 BFB07028/103 BFB07029/203 BFB07028/203 50 - TUBO LLAMA FINAL BFB07029/3 BFB07028/3 51 - GRUPO CABEZA DE COMBUSTIÓN 52 - JUNTA BFG04056/1 BFG04056/1 53 - JUNTA BFG04057/1...
  • Página 56 Ecoflam S.p.A. via Roma, 64 - 31023 RESANA (TV) - Italy - tel. 0423/715345 r.a. telefax 0423-715444 (Italy 480009 - Export 480873, 715538). http://www.ecoflam.it - e-mail: [email protected]...

Este manual también es adecuado para:

Oilflam d 300.1 pr/mdOilflam400.1 pr/mdOilflam d 400.1 pr/md

Tabla de contenido