Bradley SN2008/IR Manual De Instalación página 5

Ocultar thumbs Ver también para SN2008/IR:
Tabla de contenido
Idiomas disponibles

Idiomas disponibles

Installation
1
Install and Anchor Unit
Rough-in of plumbing lines must be completed
before unit can be properly installed.
A
Remove Access panel and with
the help of another person, place
unit in position .
B
Ensure unit is level, shimming floor unit if
necessary . Using the base as a template,
mark the floor anchor locations .
Connect Water Supply
2
to Valve Assembly
WARNING! Do not turn on water until
Step 3 is completed!
Connect stops to hot and cold water supply .
A
Connect one end of each supply hose to a
stop and the other end to the hot and cold
inlets of the Navigator
Bradley • 215-1069 Rev. J; ECN 12-00-004
Water Supply
Gang Valve
Assembly
Red Tube (to Aerator)
Green Tube (to Aerator)
Black Tube (to Aerator)
Yellow Tube (to Aerator)
Red Tube (to Aerator)
Green Tube (to Aerator)
Black Tube (to Aerator)
Yellow Tube (to Aerator)
TMV .
®
OPTIONAL TEMPERED LINE CONNECTION: Connect stop to
B
supply . Connect one end of the supply hose to the stop and the
other end to the tempered line adapter in the gang valve assembly .
15" (381) Dia .
Install a minimum of four 3/8" bolts
C
(supplied by installer) around unit at the
marked locations (eight is recommended) .
Secure unit to floor .
Navigator
TMV
Cold Supply Inlet
Stop Valve
12/04/2012
SN2008/IR
Water Supply
Gang Valve
Assembly
OPTIONAL
Tempered Line
Adapter Assembly
(S39-804)
Braided
Hose
Hot Supply Inlet
5
Tabla de contenido
loading

Tabla de contenido