Boneco 7145 Instrucciones Para El Uso página 15

Tabla de contenido
Idiomas disponibles

Idiomas disponibles

• Make sure main body is never submerged in water
(24)!
• 7147: The cleaning indicator still appears on the dis-
play after cleaning. To reset it hold down the ON/OFF
button until the clean light disappears.
• Clean the inner parts with a soft cloth. Do not use any
solvents or aggressive cleaning agents to clean the
appliance (25).
• Only use the brush to clean the membrane. This should
be done once a week. Only use the soft-bristle portion
of the brush (26).
• Change the water in the tank at least once a week if
water is standing for more than a week.
• To remove the mist outlet (27): Twist the mist outlet to
either the right or the left. Align the arrow on the mist
outlet with the arrow on the ring around the mist outlet.
Only one set of arrows on mist outlet and ring will
align. Pull up on the mist outlet once the arrows are
aligned.
Water quality maintenance
The Hydro Cell keeps humidifiers operating at their highest
level between recommended cleanings. Good for approxi-
mately one to two months, depending on the water quality,
the Hydro Cell ensures the humidifier's functionality while
providing fresh humidification performance. It starts to
work as soon as it comes in to contact with water, even
if the unit is turned off. The Hydro Cell should be changed
every one to two months*. Look at picture 28 for the posi-
tion of the Hydro Cell in the water tank of the unit. Switch off
the unit first. Contact your local retailer or check our website
www.boneco.us for reorder information.
* Depending on the water quality.
26
27
28
29
en