PERIODICAL MAINTENANCE
1) Check the robustness and the stability of the gate; particularly the leaning and/or rotation
points of the gate ( hinges).
2) Check the oil level in the hydraulic/in oil bath operators
3) Replace the hydraulic oil with the oil recommended by the producer
4) Check the function of the release
5) Check and grease the fixation pivots
6) Check the integrity of the connecting cables
7) Check the function and the conditions of the limit switch stops in opening and closing
8) Check the good status of all the apparatus which are subject to efforts (back fixation, oscillating
fork,and front fixation)
9) Check the functionality of all the accessories especially the function of all security devices
10) After having executed the periodical maintenance it is neccessary to repeat the test
and to reactivate the automation.
All the above mentioned operations must be executed by an authorised installer only.