ELECTRICAL WIRING
230V
1
2
Valve
D5228
NOTES
2
– Wires of 1 mm
section.
– The electrical wiring carried out by the installer
must be in compliance with the rules in force in
the Country.
– To remove the control-box from the burner,
loosen screw (A) (see figure) and pull towards
the arrow.
– The photoresistance is fitted directly into the con-
trol-box (underneath the ignition-transformer) on
a plug-in support.
TESTING
Check the shut-down of the burner by opening the
thermostats.
ATTENTION
Do not connect burner's grounding, to failure
indicator terminal
of the control box.
2346
~
50Hz
N
L
Switch with fuse
6A max.
N
L
3
4
5
6
Black
Capacitor
. This may result the destroy
WARNING
Do not exchange the neutral with the phase.
Remote lock-out lamp
(230V - 0.5A max.), if required
Terminal block of
7
8
9
control-box 530SE
M
~
Motor
A
RUN OF THE ELECTRICAL CABLE
1 - Grommet
2 - Cable-clamp
3 - Terminal block
5
GB
Regulating thermostat
T
Limit thermostat
T
with manual resetting
*
3
2
N - Neutral
L - Phase
- Burner-earth
S7026