DHC BT1000 El Manual Del Propietario página 14

Tabla de contenido
Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 58
WITH ACCESSORY LOADS
The system is showing normal output from the
alternator. No problem detected.
10. Press «ENTER» when charging system test is
completed. Turn all accessory loads and
engine off. Press «ENTER» to read the system
test results.
11. Press "ENTER" to press result or not.
IN-VEHIVLE TEST
This is a combination test of both battery test & system test. Please refer to
above testing procedures or follow the instructions on the display of the tester.
What is a GEL battery?
A gel battery is a lead-acid electric storage battery that:
is sealed using special pressure valves and should never be opened.
is completely maintenance-free.
uses thixotropic gelled electrolyte.
GLOSSARY
14
14
xx.xx V NORMAL
TEST OVER. TURN
OFF LOADS &
ENGINE
ALT. LOAD VOLTS
xx.xx V NORMAL
RIPPLE VOLTAGE
xx.xx V NORMAL
CRANKING VOLTAGE
xx.xx V NORMAL
ALT. IDLE VOLTS
xx.xx V NORMAL
PRINT RESULT?
YES/NO