Table For Cv - LGB 21980 Manual Del Usuario

Tabla de contenido
Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 28
Register Assignment
1
Address
2
Minimum speed
3
Acceleration delay
4
Braking delay
5
Maximum speed
8
Reset
13
Function F1 – F8 with alternative track signal
14
Function FL, F9 – F15 with alternative track signal
17
Expanded address, higher value byte
18
Expanded address, lower value byte
19
Multiple unit operation address
21
Functions F1 – F8 with multiple unit operation
22
Function FL, F9 – F15 with multiple unit operation
Bit 4: Braking mode voltage against the direction of travel
27
Bit 5: Braking mode voltage with the direction of travel
Bit 0: Direction normal/inverted
Bit 1: Number of speed levels 14/28(128)
29
Bit 2: Analog operation off/on
Bit 5: short / long address active
Alternative Formats
50
Bit 1: Analog DC
Bit 3: mfx off/on
53
Motor control – control reference
54
Motor control – control parameter K
55
Motor control – control parameter I
56
Motor control – control influence
57
steam chuff 1
58
steam chuff 2
Range
Default
Register Assignment
1 – 127
3
0 – 255
5
60
0 – 255
15
0 – 255
15
63
0 – 255
255
64
8
131
67 – 94 Speed table for speed levels 1 – 28
0 – 255
32
112
0 – 255
1
113
192 – 231
192
114
0 – 255
128
115 – 135
0 – 255
0
137
0 – 255
0
138
0 – 255
0
0/16
139
16
0/32
140
0/1
0/2
141
6
0/4
142
0/32
143
0/2
10
144
0/8
145
0 – 255
130
147
0 – 255
96
148
0 – 255
64
152
0 – 255
24
176
0 – 255
0
177
0 – 255
66
14
Multi-station announcement
Bit 0 – 3: Number of stations
Bit 4: Last announcement changes the sequence
Bit 5: Locomotive direction changes the sequence
Bit 6: Start for the sequence
Total volume
Threshhold for squealing brakes
Mapping lights in the front, mode
Mapping lights in the front, dimmer
Mapping lights in the front, cycle
Mapping phys. outputs, lights in the rear, Aux 1 – 6,
compare 112 – 114
Factor for switching range
Volume for squealing brakes
Volume for Operating sounds
Volume for whistle blast
Volume for Bell
Volume for whistle blast
Volume for Station announcements
Volume for Conductor whistle
Volume for Switching whistle
Volume for Blowing off steam
Volume for Coal being shoveled
Volume for Blowing off steam
Minimum speed in analog DC
Maximum speed in analog DC
Range
Default
0 – 15
0/16
41
0/32
0/64
0 – 255
255
0 – 255
105
0 – 255
0 – 16
1
0 – 255
255
0 – 255
20
0 – 16
0 – 255
1 – 128
128
0 – 255
180
0 – 255
180
0 – 255
255
0 – 255
180
0 – 255
255
0 – 255
255
0 – 255
180
0 – 255
180
0 – 255
180
0 – 255
180
0 – 255
180
0 – 255
115
0 – 255
255
Tabla de contenido
loading

Tabla de contenido