Chapter 3. Machine adjustment and setting up

3.1. Adjustment

1
Main switch
2
Button "DECREASE". Reduces set function values
3
Button "INCREASE". Increases set function values
A
Temperature warning light
B
Shrinking warning light
C
Sealing warning light
P
Programs selection button
D
Display. Displays selected functions and relative settings
S
Variables selection switch
(figure 3.1. page 59).
ELECTRONIC BOARD FEATURES
The machine is equipped with 6 selectionable programs:
Program nr.
P1
P2
P3
P4, P5, P6
Each program is composed by 4 variables which can be modified (in case it is not possible to set one of them, such a
variable will obviously not appear on the display):
Variable
1. Temperature
2. Sealing
3. Shrinking
4. Shrinking delay
PHASE NR. 1 = SWITCHING THE MACHINE ON
Turn the main switch (1) into pos. 1. Before using the machine, wait until the adjusting temperature is reached. This is
signalled by the extinction of the warning light (A). The display (D) turns on and the number of the currently selected
program will appear.
PHASE NR. 2 = PROGRAMS SELECTION
Push button (P) to select the number of the program.
PHASE NR. 3 = VARIABLES PROGRAMMING
Through button (S) it is possible to look through the variables of the selected program, while through buttons (2) and (3)
the memorized values can be modified. To validate modifications, press button (S) until the number of the program
appears on the display.
The fan delay time after sealing can be modified; there is not a LED indicating this variable which is shown with an "r" on
the left display, while the right one shows the time which has been set. At the end of all variables to be adjusted, the
display will show the code of the program just chosen (for example P1).
N.B.: In case during programming the SQ1 limit switch is being pressed, the unit quits the scheduling, the selected
program is executed and the display shows the number of the program.
PHASE NR. 4 = PERFORMANCE
Once all adjustments have been made, the machine is ready to start working.
APPROXIMATE TABLE OF MACHINE CICLE ADJUSTEMENT
SHRINKING TIME
6"
5"
4"
3"
2"
ERROR MESSAGES
The electronic board can detect some errors signalled by displaying the following messages on the display (D):
E 1
Machine has been switched on when the hood was lowered. Lift the hood up.
E 2
Machine has been switched on when the (S) button was pressed. Release the button. In case the error signalling
still persists, check the correct functioning of the button.
E 3
Working temperature hasn't been reached in the set time (10 min.). Check the correct positioning of the feeler.
Check heater and fuses. Reset through (P) button.
E 4
Temperature is higher than 400°C or feeler has been interrupted. Switch the machine on to reset.
Program features
Sealing only
Sealing + shrinking
Sealing + delayed shrinking to sealing end
Sealing + shrinking
Field
Field features
00 ÷ 99
corresponds to 150.....348°C (2°C each point)-(medium value 75)
0 ÷ 2.2
values expressed in seconds
0.0 ÷ 9.9
values expressed in seconds
0 ÷ 9
tenth-seconds values
PAUSE TIME
6"
7"
8"
9"
10"
12
TEMPERATURE (Field)
50
60
70
80
90
GB
Tabla de contenido
loading

Este manual también es adecuado para:

Replay 55

Tabla de contenido