Accessories/Replacement Items; Maintenance - DeVilbiss Healthcare IntelliPAP AUTOADJUST CPAP DV54 Serie Guía De Instrucciones

Dispositivo de presión positiva en las vías respiratorias
Ocultar thumbs Ver también para IntelliPAP AUTOADJUST CPAP DV54 Serie:
Tabla de contenido
Idiomas disponibles

Idiomas disponibles

1.
Obtain the optional oxygen adapter (part #7353D-601) from your homecare provider and connect it to the air supply
port on the IntelliPAP. Connect one end of the air supply tubing to the open end of the adapter and the other end of the
air supply tubing to the mask.
2.
If your mask is equipped with an oxygen port, your physician may request that you apply oxygen directly to your mask.

accessories/repLaceMeNt iteMs

replacement items
Air-inlet filter (4/pk)
Fine particle filter (4/pk)
Air supply tubing (6')
Air supply plug
Humidifier Chamber
power items
AC power cord (USA)
AC power cord (Brazil)
DeVilbiss Masks
FlexSet
Masks
®
Large, Silicone
Medium, Silicone
Small, Silicone
Large, Gel
Medium, Gel
Small, Gel
Large, ComfortTouch
Medium, ComfortTouch Silicone
Small, ComfortTouch Silicone
Large, ComfortTouch Gel
Medium, ComfortTouch Gel
Small, ComfortTouch Gel
EasyFit
Nasal
®
EasyFit Full Face

MaiNteNaNce

DaNGer
Electric shock hazard-Do not attempt to open or remove the cabinet; there are no user-serviceable components
inside. If service is required, contact your equipment provider for instructions on obtaining service. Opening or
attempting to service your device will void the warranty.
WarNiNG
Disconnect supply before servicing.
Pressure Accuracy–The IntelliPAP is designed to provide accurate pressure performance from the factory without additional
calibration. No routine service is required provided the device is used in accordance with the manufacturer's directions.
NOTE–Some countries require periodic servicing and calibration of this kind of medical device. Contact your equipment
provider for further information.
Standard Air-Inlet Filter–Check the filter every 10 days and clean it if necessary. Replace the filter every 6 months or
sooner if it is damaged. The standard filter is designed to filter particles larger than 3.0 microns in size. The IntelliPAP
MUST have the standard filter in place during operation.
Optional Fine Particle Filter–Check the filter every 10 days and replace it if it is dirty or damaged; otherwise replace the
filter every 30 days. The optional fine particle filter is designed to filter particles as small as 0.3 microns in size.
eN - 10
DV51D-602
DV51D-603
DV51D-629
DV51D-604
DV5C
DV51D-606
DV51D-612
9354L
9354D
9354S
9354GL
9354G
9354GS
Silicone
9354LR
9354DR
9354SR
9354GLR
9354GR
9354GSR
Available in Silicone (S, M, L, XL), Gel (S, M, L) or SilkGel (S, M, L). Contact
your equipment provider
Available in Silicone (S, M, L, XL), Gel (S, M, L) or SilkGel (S, M, L). Contact
your equipment provider
Heater connection cover
Oxygen adapter
Carrying case
Heated Humidifier
Chamber Sealing Gasket
DC power cord
DC battery clamp-on adapter (requires DC
Power Cord DV51D-619)
Serenity
Masks
®
Large, Silicone
Medium, Silicone
Small, Silicone
Large, Gel
Medium, Gel
Small, Gel
Large, ComfortTouch Silicone
Medium, ComfortTouch Silicone
Small, ComfortTouch Silicone
Large, ComfortTouch Gel
Medium, ComfortTouch Gel
Small, ComfortTouch Gel
DV51D-605
7353D-601
DV51D-610
DV5HH
DV5C-614
DV51D-619
DV51D-696
9352L
9352D
9352S
9352GL
9352G
9352GS
9352LR
9352DR
9352SR
9352GLR
9352GR
9352GSR
A-DV54
Tabla de contenido
loading

Tabla de contenido