Disposal Note; Programme Table - Grohe Eurosmart Cosmopolitan E 36 325 Manual De Instrucciones

Ocultar thumbs Ver también para Eurosmart Cosmopolitan E 36 325:
Tabla de contenido
Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 13
V. Mixer spindle, see fold-out pages II and III
1. Disconnect fitting from connections.
2. Remove fitting from wash basin.
Disassembly is as described in section "Setting temperature
limiter", see Fig. [8] or [10].
3. Pull out mixer spindle and replace, see Fig. [18].
Assemble in reverse order.
Replacement parts
see fold-out page I (* = special accessories)

Programme table

The infrared electronics provide seven preset programmes for selection.
Programme
1
Temporary shutoff*
2
Automatic flushing*
Flush interval
Flush duration
Usage-dependent
Usage-independent
Duration of thermal disinfection
1
*
Cleaning mode can be activated when temporary shutoff is activated. In cleaning mode, water flow is not started for
3 minutes even if an object is detected.
2
*
Automatic flushing serves to ensure water hygiene in the event of long-term non-utilisation of the fitting. Flushing is initiated
for a duration of 5 minutes after 24 hours (usage-independent) or for a duration of 1 or 5 or 10 minutes after 72 hours
(usage-dependent) after the fitting was last used.
Safety note:
Ensure free draining in the case of activated automatic flushing.
Fault / Cause / Remedy
Fault
Cause
Water not flowing
• Water supply interrupted
• Filter in solenoid valve blocked
• Solenoid valve defective
• Plug-in connector without contact
• No voltage
- Battery discharged
- Power supply unit defective
• Hands not in detection zone
• Cleaning mode activated
Water flowing
• Solenoid valve defective
continuously
• Thermal disinfection activated
Undesired water
• Sensor system detection zone set too high
flow
for local conditions
• Automatic flushing activated
Flow rate too low
• Mousseur dirty
• Filter in solenoid valve dirty
• Filters in connection hose dirty
• Water supply restricted
Mixing device
• See "Flow rate too low"
incorrect
• Limescale on mixer spindle
Care
For directions on the care of this fitting, please refer to the
accompanying Care Instructions.

Disposal note

Dispose of batteries in accordance with national
regulations.
1
2
3
4
Active
Active
Active
Active
Inactive
Active
Active
Active
-
72 h
24 h
72 h
-
5 min
5 min
10 min
-
x
x
-
x
3.5 min
3.5 min
11 min
3.5 min
Remedy
- Open shut-off valves
- Clean filter
- Replace solenoid valve
- Check plug-in connector
- Replace battery
- Replace power supply unit
- Hold hands directly under the spout
- Deactivate cleaning mode or wait 3 minutes
- Replace solenoid valve
- Wait 3.5 or 11 minutes
- Reduce range using remote control (special
accessory, prod. no.: 36 206)
- Wait 1 - 10 minutes
- Clean or replace mousseur
- Clean filter
- Clean or replace filters
- Check supply lines, open shut-off valves
- Clean or replace mixer spindle
5
6
7
Active
Inactive
Inactive
Active
Inactive
Active
72 h
-
72 h
1 min
-
5 min
x
-
x
-
3.5 min
3.5 min
3.5 min
6
Tabla de contenido
loading

Tabla de contenido