Heath Zenith SL-5407 Guia De Inicio Rapido página 3

Repuesto universal para el cabezal del detector
Tabla de contenido
Idiomas disponibles

Idiomas disponibles

TEST AND ADJUSTMENT
❒ Turn on the circuit breaker and light switch.
NOTE: Sensor has a 1
period before it will detect motion. When
first turned on, wait 1
❒ Turn the RANGE control to the mid position and
the ON-TIME control to the TEST position.
ON-TIME
10 5 1 TEST
Bottom of Sensor
Avoid aiming the control at:
• Objects that change temperature rapidly, such
as heating vents and air conditioners. These
heat sources could cause false triggering.
• Areas where pets or traffic may trigger the
control.
• Nearby large, light-colored objects reflecting
light may trigger the shut-off feature. Do not point
8 ft.
(2.4m)
70 ft.
(21m)
Maximum Range
The sensor is less sensitive to motion directly to-
wards it, most sensitive to motion across its field
of view.
Motion
Least Sensitive
595-5544-06
/
minute calibration
1
2
/
minutes.
1
2
RANGE
MIN
Maximum
Coverage Angle
Motion
Sensor
Most Sensitive
❒ Loosen the clamp screw
in the sensor ball joint and
gently rotate the sensor.
❒ Walk through the cover-
age area noting where
you are when the lights
turn on (also, the LED will
flash several times when
motion is detected). Move
the sensor head up, down,
or sideways to change the
coverage area. Keep the
sensor at least 1" (2.5 cm)
away from the lamps.
MAX
❒ Adjust the RANGE as
needed. RANGE set too
high may increase false
triggering.
❒ Secure the sensor head
by tightening the clamp
screw. Do not overtighten the screw.
❒ Set the amount of TIME you want the lights to stay
on after motion is detected (1, 5, or 10 minutes).
WARNING: Risk of fire. Do not aim the lamps
at a combustible surface within 3 ft. (1 m).
180°
SPECIFICATIONS
Range . . . . . . . . . . . . . . Up to 70 ft. (21 m) [varies with
Sensing Angle . . . . . . . . Up to 180°
Electrical Load . . . . . . . . Up t o 5 00 W att ( 4.2A) M aximum
Power Requirements . . . 120 VAC, 60 Hz
Operating Modes . . . . . . TEST, AUTO and MANUAL
Time Delay . . . . . . . . . . 1 , 5, 10 minutes
Range . . . . . . . . . . . . . . Adjustable
HeathCo LLC reserves the right to discontinue prod-
ucts and to change specifications at any time without
incurring any obligation to incorporate new features in
products previously sold.
-3-
Clamp
Screw
Ball
Joint
Aim Sensor
Down for Short
Coverage
Aim Sensor
Higher for Long
Coverage
surrounding temperature].
Incandescent [Up to 250 Watt
maximum each lamp holder.]
MODE
Tabla de contenido
loading

Tabla de contenido