4. Fuel
LE-HGG 110, HGG 110 Niro, HGG 171 Niro:
Commercially available propane (DIN 51622)
Commercially available butane (DIN 51622)
Pressure reducer 300 mbar
HGG 300 Niro:
Commercially available propane (DIN 51622)
Pressure reducer 1,5 bar
The appliance can be operated in conjunction with
any 5 kg or 11 kg gas cylinder or an even bigger
container. Be sure to use only the following
equipment when connecting the unit to a gas
cylinder: For model HGG 110 Niro/HGG 171 NIRO
/LE-HGG 110 a pressure reducer with an output
pressure of 300 mbar (HGG 300 Niro: 1,5 bar) with
DIN 4811 Part 1, together with a liquefied gas pipe in
compliance with DK 6 according to DIN 4815 Part 2.
5. Ventilation
Caution:
The heater must only be used in well ventilated
areas (heater is not intended for use in enclosed
spaces). The continuous presence of persons in
these rooms is forbidden. If more than one heater is
used in one room, be sure to provide for
correspondingly more fresh air circulation.
6. Maintenance
Always first unplug the heater before any
maintenance or repairs.
Disconnect the gas hose from the gas cylinder.
Regularly check that the gas hose and its screw
connections are sealed. Only original replacement
parts and hoses must be used. Hoses must meet
the specifications in DIN 4815 Section 2.
Adjustment of the ignition electrode should be
checked as shown in picture 6.
10
16.01.2006
12:47 Uhr
Seite 10
7. Terminal diagram (Pic 7)
Q1 On/Off switch
F1 Safety thermostat
M1 Fan motor
Y1 Thermoelectric ignition fuse
Y2 Safety solenoid valve
B1 Thermoelement
B2 Piezo ignition
B3 Ignition electrode
B4 Burner