EVCO S.p.A. | EVBOX1 | Data sheet ver. 3.0 | Code 104BOX1E304 | Page 5 of 8 | PT 25/19
d20
0
500
min
d21
0
500
min
d22
0.0
10.0
°C/°F (1)
d25
0
1
- - -
d26
0
99
h
PARAM.
MIN.
MAX.
U.M.
A0
0
1
- - -
A1
-99.0
99.0
°C/°F (1) -10.0
A2
0
2
- - -
A4
-99.0
99.0
°C/°F (1)
A5
0
2
- - -
A6
0
240
min
A7
0
240
min
A8
0
240
min
A9
0
240
min
A10
0
240
min
A11
0.1 (5)
15.0
°C/°F (1)
A12
0
2
- - -
PARAM.
MIN.
MAX.
U.M.
F0
0
5
- - -
F1
-99.0
99.0
°C/°F (1)
F2
0
2
- - -
F3
0
15
min
F4
0
240
s
F5
0
240
s
F6
0
1
- - -
F7
-99.0
99.0
°C/°F (1)
F8
0.1 (5)
15.0
°C/°F (1)
F9
0
240
s
F11
0.0
99.0
°C/°F (1)
F12
0
240
s
F13
0
240
sx10
F14
0
240
sx10
PARAM.
MIN.
MAX.
U.M.
i0
0
5
- - -
i1
0
1
- - -
i2
-1
240
min
i3
-1
120
min
i4
0
1
- - -
i5
0
9
- - -
i6
0
1
- - -
i7
0
120
min
i8
0
15
- - -
i9
1
999
min
i10
0
999
min
i13
0
240
- - -
i14
0
240
- - -
i15
0
9
- - -
i16
0
1
- - -
i17
0
240
s
PARAM.
MIN.
MAX.
U.M.
u1
0
12
- - -
u1
0
12
- - -
u1
0
12
- - -
u2
0
1
- - -
180
minimum consecutive time the compressor is switched on such as to provoke the defrost activation (0 = the defrost will never be activated
due to the effect of this condition)
200
minimum consecutive time the compressor is switched on after the device is switched on or after the activation of the "overcooling" function
such as to provoke the defrost activation (0 = the defrost will never be activated due to the effect of this condition)
2.0
evaporator temperature above which the defrost interval count is suspended ("evaporator temperatures average + d22"; only if d8 = 3);
see also d18
0
enabling the outlet air temperature probe as defrost probe during the evaporator temperature probe error (code "Pr2"; 1 = YES); see also
d26
6
defrost interval due to the effect the outlet air temperature probe works as defrost probe during the evaporator temperature probe error (code
"Pr2"); see also d25 (0 = the defrost will never be activated due to the effect of this condition)
DEF.
TEMPERATURE ALARMS
0
temperature associated to the minimum temperature alarm (code "AL"; 0 = if P4 = 0, 1, 2 or 3, room temperature | if P4 = 4, CPT
temperature; 1 = evaporator temperature)
temperature below which the minimum temperature alarm (code "AL") is activated; see also A0, A2 and A11
0
minimum temperature alarm (code "AL") type (0 = absent; 1 = "working setpoint - |A1|"; 2 = "A1")
10.0
temperature above which the maximum temperature alarm (code "AH") is activated; see also A5 and A11
0
maximum temperature alarm (code "AH") type (0 = absent; 1 = "working setpoint + |A4|"; 2 = "A4")
120
maximum temperature alarm (code "AH") delay after the device is switched on
15
temperature alarm (code "AL" and code "AH") delay
15
maximum temperature alarm (code "AH") delay after the evaporator fan standstill finishes
15
maximum temperature alarm (code "AH") delay after the door switch input is deactivated
1
duration of an interruption of power supply such as to provoke the memorization of the power supply interruption alarm (code "PF"; only
available in EVB1214, EVB1216, EVB1236 and EVB1256 or if EVIF25SWX module is connected)
2.0
"A1" and "A4" differential
1
type of signal for the power supply interruption alarm (code "PF"; only available in EVB1214, EVB1216, EVB1236 and EVB1256 or if EVIF25SWX
module is connected; 0 = LED "HACCP"; 1 = code "PF", alarm buzzer and LED "HACCP"; 2 = code "PF", alarm buzzer if the duration of the
interruption is longer than A10 and LED "HACCP")
DEF.
EVAPORATOR FAN AND CONDENSER FAN
1
evaporator fan activity during the normal operation (0 = switched off; 1 = switched on; see also F13, F14, i10, HE2, H01... H14 (8);
2 = according to the compressor; see also F13, F14, i10, HE2, H01... H14 (9); 3 = according to F1; see also F13, F14, i10, HE2, H01... H14
(10); 4 = switched off if the compressor is switched off | according to F1 if the compressor is switched on; see also F13, F14, i10, HE2, H01...
H14 (11); 5 = according to F6)
-1.0
evaporator temperature above which the evaporator fan is switched off (only if F0 = 3 or 4); see also F8
0
evaporator fan activity during the defrost and the dripping (0 = switched off; 1 = switched on; 2 = according to F0)
0
evaporator fan standstill maximum duration; see also F7
60
time the evaporator fan is switched off during the low percentage of relative humidity operation; see also F5
10
time the evaporator fan is switched on during the low percentage of relative humidity operation; see also F4
0
low or high percentage of relative humidity operation (only if F0 = 5; 0 = low; 1 = high)
5.0
evaporator temperature below which the evaporator fan standstill is finished ("working setpoint + F7"); see also F3
2.0
"F1" differential
0
delay in switching off the evaporator fan after the compressor is switched off
15.0
condenser temperature above which the condenser fan is switched on ("F11 + 2.0 °C/4 °F")
30
delay in switching off the condenser fan after the compressor is switched off
30
time the evaporator fan is switched off during the "energy saving" function; see also F14, i10, HE2, H01... H14 (only if F0 = 1, 2, 3 or 4)
30
time the evaporator fan is switched on during the "energy saving" function; see also F13, i10, HE2, H01... H14 (only if F0 = 1, 2, 3 or 4)
DEF.
DIGITAL INPUTS
3
effect provoked by the door switch input activation (0 = absent; 1 = the compressor and the evaporator fan will be switched off; see also
i3; 2 = the evaporator fan will be switched off; see also i3; 3 = the room light will be switched on; 4 = the compressor and the evaporator
fan will be switched off and the room light will be switched on; see also i3; 5 = the evaporator fan will be switched off and the room light
will be switched on; see also i3); see also i4
0
type of door switch input contact (0 = normally open; 1 = normally closed)
30
door switch input alarm (code "id") signal delay (-1 = the alarm will not be signalled)
15
maximum duration of the effect provoked by the door switch input activation on the compressor and the evaporator fan (-1 = the effect will
last as long as the input will be deactivated)
0
memorizing the door switch input alarm (code "id"; 1 = YES)
7
effect provoked by the multipurpose input activation (0 = absent; 1 = the "energy saving function" will be activated; 2 = the multipurpose
input alarm (code "dI2") will be activated; 3 = the high pressure switch alarm (code "iSd") will be activated; 4 = the auxiliary output will
be switched on; 5 = the device will be switched off; 6 = the low pressure switch alarm (code "LP") will be activated; 7 = the compressor
thermal switch alarm (code "C1t") will be activated; 8 = the compressor 2 thermal switch alarm (code "C2t") will be activated; 9 = the man
in room alarm (code "MiC") will be activated)
0
type of multipurpose input contact (0 = normally open; 1 = normally closed)
0
if i5 and/or i15 = 2, multipurpose input alarm (code "dI2") signal delay | if i5 and/or i15 = 3, delay in switching on the compressor after the
multipurpose input is deactivated
0
number of multipurpose input alarms (code "dI2") such as to provoke the high pressure switch alarm (code "iSd"; only if i5 and/or i15 =
3; 0 = absent)
240
time that must elapse in absence of multipurpose input alarms (code "dI2") in order that the alarm counter is reset (only if i5 and/or i15 =
3)
0
time that must elapse in absence of door switch input activations (after the room temperature, if P4 = 0, 1, 2 or 3 | after the CPT temperature,
if P4 = 4, has reached the working setpoint) in order that the "energy saving" function is activated; see also r4, F14, F15 and HE2 (0 = the
function will never be activated due to the effect of this condition)
180
number of door switch input activations such as to provoke the defrost activation (0 = the defrost will never be activated due to the effect
of this condition)
32
minimum time the door switch input is activated such as to provoke the defrost activation (0 = the defrost will never be activated due to the
effect of this condition)
9
effect provoked by the multipurpose 2 input activation (0 = absent; 1 = the "energy saving function" will be activated; 2 = the multipurpose
input alarm, code "dI2", will be activated; 3 = the high pressure switch alarm, codes "dI2" and "iSd", will be activated; 4 = the auxiliary
output will be switched on; 5 = the device will be switched off; 6 = the low pressure switch alarm, code "LP", will be activated; 7 = the
compressor thermal switch alarm, code "C1t", will be activated; 8 = the compressor 2 thermal switch alarm, code "C2t", will be activated;
9 = the man in room alarm, code "MiC", will be activated)
0
type of multipurpose 2 input contact (0 = normally open; 1 = normally closed)
30
low pressure switch alarm (code "LP") delay after the device is switched on
DEF.
DIGITAL OUTPUTS
0
load managed by the digital output K4 (only available in EVB1204 and EVB1214; 0 = room light; 1 = demisting heater; 2 = auxiliary output;
3 = alarm output; 4 = door heater; 5 = neutral zone operation heater; 6 = condenser fan; 7 = compressor 2; 8 = defrost 2; 9 = evaporator
fan 2; 10 = pump down valve; 11 = on/stand-by; 12 = man in room)
6
load managed by the digital output K5 (not available in EVB1204 and EVB1214; 0 = reserved; 1 = demisting heater; 2 = auxiliary output;
3 = alarm output; 4 = door heater; 5 = neutral zone operation heater; 6 = condenser fan; 7 = compressor 2; 8 = defrost 2;
9 = evaporator fan 2; 10 = pump down valve (reserved in EVB1246 and EVB1256); 11 = on/stand-by; 12 = man in room)
6
load managed by the digital output K3 (only available in EVB1226, EVB1236 and EVB*XC; 0 = reserved; 1 = demisting heater; 2 = auxiliary
output; 3 = alarm output; 4 = door heater; 5 = neutral zone operation heater; 6 = condenser fan; 7 = compressor 2; 8 = defrost 2;
9 = evaporator fan 2; 10 = pump down valve (reserved in EVB1246 and EVB1256); 11 = on/stand-by; 12 = man in room)
0
enabling the room light and the auxiliary output switch on/off in manual mode when the device is switched off (1 = YES)