EVCO S.p.A. | EVBOX1 | Data sheet ver. 3.0 | Code 104BOX1E304 | Page 3 of 8 | PT 25/19
NTC analog inputs (10 KΩ @ 25 °C, 77 °F)
Kind of sensor:
ß3435.
Working range:
from -50 to 120 °C (from -58
to 248 °F).
Accuracy:
±0.5 % of the full scale.
Resolution:
0.1 °C (1 °F).
Protection:
none.
Pt 1000 analog inputs (1 KΩ @ 0 °C, 32 °F)
Working range:
from -99 to 150 °C (from -99
to 300 °F).
Accuracy:
±0.5 % of the full scale.
Resolution:
0.1 °C (1 °F).
Protection:
none.
4-20 mA analog inputs
Input resistance:
≤ 200 Ω.
Accuracy:
±0.5 % of the full scale.
Resolution:
0.01 mA.
Protection:
none; the maximum current al-
lowed for the input is 25 mA.
Digital inputs: 3 inputs which can be set via configuration
parameter for normally open or normally closed contact
(door switch, multipurpose and multipurpose 2).
5 VDC, 2 mA digital inputs (free of voltage)
Power supply:
none
Protection:
none.
Digital outputs: up to 6 outputs:
-
two 30 res. A @ 250 VAC SPST electromechanical relays
(compressor and evaporator fan)
-
one 16 res. A @ 250 VAC SPST electromechanical relay
(defrost)
-
one 16 res. A @ 250 VAC SPST electromechanical relay
(room light; not available in EVB1204 and EVB1214)
-
one 8 res. A @ 250 VAC SPST electromechanical relay
(which can be set via configuration parameter for room
light, demisting heater, auxiliary output, alarm output,
door heater, neutral zone operation heater, condenser
fan, compressor 2, defrost 2, evaporator fan 2, pump
down valve, on/stand-by or man in room; only avail-
able in EVB1204 and EVB1214)
-
one 8 res. A @ 250 VAC SPST electromechanical relay
(which can be set via configuration parameter for de-
misting heater, auxiliary output, alarm output, door
heater, neutral zone operation heater, condenser fan,
compressor 2, defrost 2, evaporator fan 2, pump down
valve, on/stand-by or man in room; not available in
EVB1204 and EVB1214)
-
one 8 res. A @ 250 VAC SPDT electromechanical relay
(which can be set via configuration parameter for de-
misting heater, auxiliary output, alarm output, door
heater, neutral zone operation heater, condenser fan,
compressor 2, defrost 2, evaporator fan 2, pump down
valve, on/stand-by or man in room; not available in
EVB1204 and EVB1214).
The device ensures a reinforced insulation among each con-
nector of the digital outputs and the remaining parts of the
device.
Unipolar stepper electronic expansion valves driver:
12 VDC, 260 mA max.
Type 1 or type 2 actions: type 1.
Additional features of type 1 or type 2 action: C.
Displays: 3 digits custom display, with decimal point and
function icons.
Communication ports: 1 MODBUS RS-485 port (with
MODBUS slave communication protocol).
Signal and alarm buzzer: incorporated.
Connectivity:
Wi-Fi
(only
available
EVB1206N9XWX).
Wi-Fi output power (EIRP): 11b: 67.5 mW and 11g:
71.1 mW, 11n (HT20) 56.5 mW.
Wi-Fi frequency range: 2,412... 2,472 MHz.
Security protocols: open, WEP, WPA/WPA2 Personal aka
PSK.
Encryption methods: TKIP, CCMP.
Unsupported modes: mixed WPA/WPA2 PSK using TKIP
+ CCMP WPA/WPA2 Enterprise aka EAP.
in