 Minimum Air: Allows activating the minimum air function ON or deactivating it OFF in
system dampers. This allows the entry of a minimum air flow in zones where the set
temperature has been reached. In this way, the system ensures the ventilation air supply
through the air-conditioning pipes. If the zone is deactivated, the damper will be totally
closed.
Note: The change of this parameter affects all installation motorised dampers. It is not recommended for
intelligent grill RINT and RIC.
 Installation master: Allows imposing the operation mode of system 1 to the rest of
systems connected to an AZXCCPC or AZIACCV module in semi-forced mode.
By default, it is deactivated OFF. If you want to activate this option, select the option ON.
 Q-Adapt: It is a function of the Airzone systems whose objective is to adapt the air flow
to the system/zone requirements. For Cen / Flexa 2.0 / IBPro 6 systems, you can choose
from the following values:
-
Q-Power: Promotes the increased air flow in the speed map.
Q-Standard: Default configuration.
-
-
Q-Silence: Promotes the noise reduction.
Q-Minimum: The system operates at minimum speed.
-
For Acuazone / IBPro 32 / Innobus Air systems you can choose between the following
values:
-
Automatic:
proportionally its total weight (100) between
the
configured.
-
Manual: Allows modifying the zone total
weight with values between 1 and 99. The
zone weight is configured from the zone
parameters (see section 3.3.2).
 Relay: This option allows modifying the operating
logic of the VMC relay to make it work with Boiler
logic and vice versa.
 Info: This option displays information about the
system, its configuration, firmware versions, and
others (Fig. 14).