Local ventilation
the local ventilation of the zone.
Horizontal slats
the tilt angle of the horizontal slats. The available options are: H1, H2, H3, H4 and
Swing.
H1 position is completely horizontal and H4 is completely vertical. The Swing option does
an auto sweep of all slats from position H1 to H4.
Vertical slats
tilt angle of the vertical slats. The available options are: V1, V2, V3, V4 and Swing.
V1 position has the slats fully rotated to the left and V4 fully rotated to the right. The
Swing option does an auto sweep of all slats from position V1 to V4.
To return to the zone control screen, press again
3.3. Navigation configuration mode
Important: If you are not an authorized technician, do not modify any value of this menu.
From this navigation mode, the configuration parameters at the user level of the different
systems/zones associated with the Webserver can be displayed and modified. Depending on
the selected option in the navigation menu, the control zone will adapt the information
represented. This navigation mode is only available for administrator profile.
The configuration parameters are divided into two parts:
Systems parameters.
Zone parameters.
3.3.1. Systems parameters
The Webserver allows displaying and modifying the configuration parameters of the associated
systems. These parameters vary according to the type of Airzone system and the devices
connected to it that may not be available. To access this option, select from the navigation
menu the desired system and then activate the configuration mode
If you want to modify any parameter, press the parameter and select the desired value
(Fig. 12).
System direction: Read-only parameter that indicates the selected system address.
Cooling Set point temperature: This parameter allows selecting the minimum set point
temperature in cooling mode
26ºC (in steps of 1ºC). The parameter OFF deactivates system cooling modes.
38
(Only available for Innobus Air)
(Only available in zones controlled by IR module)
(Only available in zones controlled by IR module)
. It is possible to select between the values 18ºC and
: This option allows activating/deactivating
: This option allows defining
: This option allows defining the
or press the icon
.
.