Unpacking And Contents; Introduction; Features; Alignment Marks - Amprobe Multimeter Serie Manual De Uso

Tabla de contenido
Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 67
Before and after hazardous voltage measurements, test the voltage function on a known
source such as line voltage to determine proper meter functioning.
Keep your hands/fingers behind the hand/finger barriers (of the meter and the test leads)
that indicate the limits of safe access of the hand-held part during measurement.
inspect test leads, connectors, and probes for damaged insulation or exposed metal before
using the instrument. if any defects are found, replace them immediately.
This Clamp-on meter is designed to apply around or remove from uninsulated hazardous
live conductors. individual protective equipment must be used if hazardous live parts of
the installation could be accessible.
exercise extreme caution when: measuring voltage >20 V // current >10 mA // AC power
line with inductive loads // AC power line during electrical storms // current, when the fuse
blows in a circuit with open circuit voltage >1000 V // servicing CRT equipment.
Remove test leads before opening the case to change the battery.
Disconnect circuit power and discharge all high-voltage capacitors before testing
resistance,continuity, diodes, or capacitance.
To avoid false readings, which could lead to possible electric shock or personal injury,
replace the batteries as soon as the low battery indicator (�) appears.

UNPACkINg AND CoNTENTS

Your shipping carton should include
1
ACDC-100 or ACDC-100 TRMS
1
Test lead set
2
1.5V AAA Battery (installed)
1
Users Manual
1
Carrying Case
if any of the items are damaged or missing, immediately return the complete package to the
place of purchase for an exchange.

INTRoDUCTIoN

The ACDC-100 and ACDC-100 TRMS Clamp-on meters are 1000 Amp / 600 V clamp meters
with 50 mm jaw opening for industrial applications. The features include large conductor
size and in-rush current measurement along with AC / DC voltage, AC / DC current, Resistance,
Continuity and Diode Tests.

fEATURES

Alignment marks (see fig. 1)
place conductor within the jaws at the intersection of the indicated marks as close as possible
to maximize the accuracy of the reading.
MAX � / HoLD �
The holD feature freezes the display when the � button is pressed. The MAx feature
compares and displays the measured maximum value as fast as 30ms with auto-ranging
capability.
6
Tabla de contenido
loading

Este manual también es adecuado para:

Acdc-100 trmsAcdc-100

Tabla de contenido