Bosch EXACT Manual Original página 27

Tabla de contenido
Idiomas disponibles

Idiomas disponibles

Maintenance tab (for EXACT 12V only)
Parameter
Maintenance Counter Visualisation Activates the maintenance counter
Maintenance Counter Value
Maintenance Counter Reset Value The reset value can be set.
Maintenance Counter Warning
Maintenance Counter Tool Lock
Bosch Power Tools
Description
The Maintenance Counter Value indicates the
current status of the counter.
Reset button
The warning ensures that users are informed in
good time that the screwdriver should be main-
tained within the set value.
Locks the screwdriver when it reaches the set
value.
English | 27
Value
Off
Maintenance counter visualisation
switched off
Red LED on the battery indicator
flashes
Maintenance counter visualisation
switched on
Work area light flashes
Maintenance counter visualisation
switched on
Read-only, can be reset to the set
maintenance counter reset value by
pressing the reset button
The maintenance counter reset value
can be set from 1 to 100,000.
The reset button transmits the value
to the maintenance counter. This
value is transmitted when writing the
parameters to the screwdriver.
The warning can be set from 1 to
100,000.
Off
Maintenance counter tool lock
switched off
On
Maintenance counter tool lock
switched on
1 609 92A 606 | (20.01.2021)
Tabla de contenido
loading

Tabla de contenido