HAZARDS ASSESSMENT

In order to select appropriate eye and face protecting devices, a hazard and risk analysis shall be carried out by well-
trained experts and the eye, face and/or head protector never shall be used in environments with a higher risk rating than
the protection rating indicated on the marking. According to this Hazard Risk Assessment, the AFP-25 Helmet Mounted
Arc Flash Faceshield shall be combined with further arc flash protective PPE such as helmets, garments, gloves, etc.
Inappropriate usage, e.g. at higher arc exposures, may cause severe damages to the life and health of the user.
WHAT IS THE
ORIGIN / PROJECT RISK
RISK?
By contact:
Fire, Explosions
General actions
Wear due to use.
Thermal hazards
Electric equipment
produced by
malfunction, heat from an
electric arc
arc flash, exposed flame
Lack of visibility
Insufficient perception
High speed
Particles projected to high
impacts
speed
Burns to the eyes
UV radiation

LIMITATIONS - WARNING

Failure to follow these instructions can result in a permanent impairment of sight or other serious personal injury.
WHAT FACTORS SHOULD WE TAKE INTO ACCOUNT FROM THE
POINT OF VIEW OF SAFETY FOR THE CHOICE / USE OF PPE?
Protection of the face and portions of the head worn with equally
rated helmets, balaclava, shirt, pants, gloves and boots
Resistance to scratching
Level of heat exposure from an arc flash, small splash of molten metal
(copper, iron or projected) from an arc flash
High visibility attachments on clothing, retro reflection, increased
lighting in work areas
Select the correct face-shield according to the energy of the possible
projected particles
Select the correct filter for the related use. Do not look directly to the
luminous source
8

MARKINGS

Explanation of markings:
MARK
MEANING
2C-2
UV filter, improved colour recognition
JSP
Manufacturers Trademark
1
Optical class
B
Medium energy impact (high speed test; 6 mm steel ball at 120 m/s at room temperature)
Resistance to short circuit electrical arc, Arc Protection Class 2 (423 kJ/m² ~ 10,1 cal/cm², Open-Box
8-2-2
Test), Light Transmittance Class 2 (VLT < 50 %) as per GS-ET-29
K
Resistant to surface damage by fine particles
Protection against the thermal effect of the electric arc.
CE Mark with ID number of Notified Body
0161
(required for Cat. III products according to Annex II of the PPE REGULATION 2016/425)
0086
Conformity to UK legislation SI 2018 No. 390.

CONTACT

In case of any question, please contact the JSP technical Service Team:
Phone: +44 1993 826051
The declaration of conformity can be downloaded from documents.jspsafety.com