Use the depth gauge to measure down to the gear shaft.
Note down this value as (B).
Example: B = 62.3 millimeters
Second measurement for (K2)
Measure the distance from the ruler down to the gauge block.
Make this measurement as precisely as possible by taking readings from two opposite positions.
Thus, the determined value will be more precise, and any inaccuracy caused by a „tilting" on the
engaging bearing will be minimized. Take the mean value of both measurements on the gauge
block. Note down the value as (A).
Example: A= 63.5 mm
Calculate the difference of the 2 values A - B = ?
In our example the calculation is as follows:
63.5 mm – 62.3 mm = 1.2 mm
Refer to the below table for the required thickness of the dial.
from
0,71 mm
0,91 mm
1,11 mm
1,31 mm
1,51 mm
1,71 mm
1,91 mm
2,11 mm
2,31 mm
2,51 mm
2,71 mm
In our example we need a 1.2 mm thick dial.
Never use more than a single dial. Never place 2 dials on top of each other to reach the required
thickness. Following this procedure, the position of the bearing K2 will be adjusted.
ENVIRONMENTAL PROTECTION
Recycle unwanted materials instead of disposing of them as waste. All tools, accessories
and packaging should be sorted, taken to a recycling centre and disposed of in a manner
which is compatible with the environment. Contact your local solid waste authority for
recycling information. Dispose of this product at the end of its working life environmentally.
BGS technic KG
Bandwirkerstr. 3
D-42929 Wermelskirchen
Your reading for the bearing K2
Tel.: 02196 720480
Fax.: 02196 7204820
to
0,9 mm
1,1 mm
1,3 mm
1,5 mm
1,7 mm
1,9 mm
2,1 mm
2,3 mm
2,5 mm
2,7 mm
2,9 mm
required dial
0,8 mm
1,0 mm
1,2 mm
1,4 mm
1,6 mm
1,8 mm
2,0 mm
2,2 mm
2,4 mm
2,6 mm
2,8 mm