7.3

Sensing range setting

8020355.1DS8/2021-11-24 | SICK
Subject to change without notice
Table 12: Application conditions
Minimum distance in mm (y) between the set sensing
range and background (white, 90%)
y
140
WTS26P-xxxxx1xx
120
18%/90%
1
100
6%/90%
80
60
40
20
0
0
400
800
Figure 15: Characteristic line: WTS16
Sensing range on black, 6% remission
1
Sensing range on gray, 18% remission
2
Sensing range on white, 90% remission
3
1
40
150
700
2
25
150
3
10
150
0
150
300
500
700
(5.91)
(11.81)
(19.69)
(27.56)
Distance in mm (inch)
A
Adjustment range
A = Detection distance (depending on object remission)
WTS26x-xxxxxx2xAxx with Teach-Turn adjustment:
The sensing range is adjusted by pressing the teach-in button (approx. 1-3 seconds).
Depending on the requirements, the potentiometer can be used for fine-tuning (without
pressing the teach-in button).
Clockwise rotation: Sensing range increased
Counterclockwise rotation: Sensing range reduced
The sensing range can also be adjusted using just the potentiometer. We recommend
placing the object within the sensing range, e.g.
sensing range has been adjusted, the object is removed from the path of the beam,
which causes the background to be suppressed. The digital output changes
2
Example:
3
Sensing range on black, 6%,
90%/90%
x = 500 mm, y = 25 mm
x
1,200
1,600
Distance in mm
900
1,000
1,000
(39.37)
BluePilot:
Sensing range
indicator (blue LED)
Teach-Turn
adjustment
see figure 16, page
O P E R A T I N G I N S T R U C T I O N S | WTS26
7
COMMISSIONING
white background (90%)
x
y
30. Once the
(table
4).
29
en