66
iQ Series
iQ DSP Menu Structure
Fullrange
Model "xyz"
PROCESS
MODEL
(alt., MODEL active)
EQ
Speech
Playback
Low/ High Shelving
Sub menu
Parametric 1 & 2
XOVER
Sub Menu
Subwoofer
Function
Choose from different sound Models, either the
Model "xyz"
Turbosound signature voicing or a DSP model of
an industry standard product.
Sets the frequency response to the default
None
None
setting.
Sets the frequency response to a typical live
Live
Live
sound setting.
Sets the frequency response for optimal speech
Speech
intelligibility.
Sets the frequency response ideal for Music
Playback
playback.
Lets you define your own frequency response
User
User
setting by entering the corresponding sub menu.
Low/ High Shelving
Lets you define a low and high shelving filter.
Lets you define a parametric bell-type EQ
Parametric 1 & 2
(Frequency, Qual and Gain).
Unit is set for default full range/ subwoofer
None
None
reproduction.
Preset with ideal settings for use in combination
—
iQ8
with iQ8 fullrange speaker.
Preset with ideal settings for use in combination
—
iQ10
with iQ10 fullrange speaker.
Preset with ideal settings for use in combination
—
iQ12
with iQ12 fullrange speaker.
Preset with ideal settings for use in combination
—
iQ15
with iQ15 fullrange speaker.
Preset with high pass alignment for iQ15B
iQ15B
—
subwoofer.
Preset with high pass alignment for iQ18B
iQ18B
—
subwoofer.
User crossover sub menu for combination with
User
User
other fullrange or subwoofer speaker systems.
Select the desired crossover frequency:
Freq
Freq
For Fullrange Systems: 75 Hz to 400 Hz
For Subwoofer Systems: 50 Hz to 150 Hz
Phase
Phase
Adjust the absolute phase (0° or 180°)
Fullrange
Auto
FBQ
Single
Learn
Reset
Input
SETUP
INPUT
(page 1)
Channel
Trim
Remote
VU
Stand
POSITION
Wall
Ceiling
Corner
Delay
DELAY
Unit
Limit
SETUP (page 2)
LIMITER
Quick Start Guide
Subwoofer
Function
Automatically sets as many filters as required.
Whenever a new feedback frequency is
Auto
discovered, the first filter will be released to
attenuate the new frequency, and so forth.
Activates the FBQ (feedback detection)
Single
functionality, up to 8 feedback filters.
Automatic procedure which searches for
feedback frequencies and locks settings after all
8 filters have been set.
WARNING!
Learn
Please use ear protection during this
procedure. The feedback signal may
approach the system's maximum level,
which may cause hearing damage!
Reset
Resets all filters.
Lets you choose the audio input source.
Choose between 'Analogue', 'Ultranet' (e.g., P16
monitoring system or M32 audio via ULTRANET)
and 'Auto' (automatically switches to Analogue,
Input
when no ULTRANET is connected).
The page also shows the hardware (e.g., HW: A
or B) and the firmware version (e.g., FW: V2.2).
Channel
Select the ULTRANET P16 digital input channel.
Adjusts the input gain of the ULTRANET digital
Trim
inputs in a range
fm +10 dB to - 30 dB
Enables ULTRANET remote control functionality
Remote
in order to protect against misuse.
Displays the respective input level of all 16
VU
channels receiving via ULTRANET; only visible
when ULTRANET input is selected.
For positioning the speaker on a pole mount
Floor
stand (fullrange) or on the floor (subwoofer).
For positioning the speaker on or next to a
Wall
wall (fixed install); alternatively as a monitor
speaker (wedge).
For positioning the speaker on a wall next to the
—
ceiling (fixed install).
For positioning the speaker in a corner next to
Corner
the ceiling (fixed install); For positioning the
speaker in a corner (subwoofer).
Adjusts the amount of delay (max 300msec =
Delay
103.08m or 338.19 feet).
Unit
Selects between msec, meter and feet.
Adjust the limiter threshold for the input
signal (from OFF up to -30 dB). This threshold
Limit
adjustment allows you to set a max output power
which is below the iQ system's rated max output.
67