1. Safety Guidelines
1. Follow the installation instructions.
2. Use the appliance
• according to its intended use
• in good condition
• with due regard to safety and risk of danger.
3. Note that the appliance is exclusively for use in the appli-
cations detailed in these installation instructions. Any
other use will not be considered to comply with require-
ments and would invalidate the warranty.
4. Please take note that any assembly, commissioning,
servicing and adjustment work may only be carried out by
authorized persons.
5. Immediately rectify any malfunctions which may influence
safety.
2. Description of function
The domestic water station combines backflow preventer,
reverse rinsing fine filter, pressure reducing valve and shut-off
valve (not included on HS10S-ZS) into one unit.
Water flows first through the check valve. This causes the
valve stem to push against the spring force and open the
valve.
The downstream reverse rinsing fine filter holds back any dirt
particles in the water. These particles are then completely
flushed out by reverse rinsing.
Filters with Double Spin Technology have turbine blades
which circulate the water and thereby set the rotor on the
upper filter into a rotational motion. The internal impeller
rinses off particles that have adhered to the upper filter at the
intersecting points with the rotor.
The integral pressure reducing valve functions on a balanced
force principle whereby the force exerted by a diaphragm is
balanced against the force of an adjustment spring. The inlet
pressure has no influence on opening or closing of the valve.
Inlet pressure fluctuation does not therefore affect the outlet
pressure.
3. Application
Medium
Water
Inlet pressure Max. 16 bar with clear filter bowl
Max. 25 bar with red-bronze filter bowl
Outlet pressure1.5 - 6.0 bar
The filter is constructed for drinking water installations. In
case of a process water application the filter has to be proven
individually.
Honeywell GmbH
GB

4. Technical data

Installation position
Horizontal, with filter bowl downwards
Operating temperature max. 40°C with clear filter bowl
max. 70°C with brass filter bowl (max.
operating pressure 10 bar)
Operating pressure
Min. 1.5 bar
Connection size
1
5. Scope of delivery
The domestic water station comprises:
• Housing with inlet and outlet pressure gauges
• Check valve on inlet
• Test point for check valve
• Fine filter in clear filter bowl
• Ball valve with drain connection
• Spring bonnet with adjustment knob and setting scale
• Valve insert complete with diaphragm and valve seat
• Threaded or soldered union connections
• Shut-off valve (not included on HS10S-ZS)
• Double ring wrench
6. Options
HS10S-...AA =
Threaded socket, upper/lower throughput
width 105/135 μm
HS10S-...AAM = Red-bronze filter cup, threaded socket,
upper/lower throughput width 105/135 μm
HS10S-...ZS =
Threaded socket, without shut-off valves,
upper/lower throughput width 105/135 μm
Connection size
7. Assembly
7.1. Installations Guidelines
• Install in horizontal pipework with filter bowl downwards
- This position ensures optimum filter efficiency
• Install shutoff valves
• Ensure good access
- Pressure gauge can be read off easily
- Degree of contamination can be easily seen with clear
filter bowl
- Simplifies maintenance and inspection
• The installation location should be protected against frost
• Fit immediately after water meter
- Corresponds to DIN 1988, Part 2