HEATER INSTALLATION

!
WARNING
This Heater MUST be permanently Installed and hard
wired by an authorised/licenced person. Do Not perform
maintenance, or carry out installation or assembly
procedure while electrical power is switched on.

REMOVE PACKAGING MATERIAL

All packaging material must be removed from heater before installation.
1. Remove warning note from front of
heater
2. Remove 3 screws & front cover
3. Remove packing material around
heating elements
4. Check element markings at both
ends of heater. Ensure marks on
heating element are in line with
marks on end cap.
5. Assemble front cover & 3 screws
6
All manuals and user guides at all-guides.com
www.bromicheating.com
HEATER INSTALLATION
!
WARNING
DO NOT MOUNT THE HEATER VERTICALLY!
Heater MUST be installed so that the tube elements
are horizontal. Failure to do this will cause the heating
element within the tube to sag and cause premature
burnout. Installing vertically will void the manufacturers
warrant
y.

INSTALLATION CLEARANCES

FOR 2000W & 3000W MODELS
2000W & 3000w models must be installed with the minimum
installation clearances shown in below diagrams. 2000W &
3000W models are supplied with short mounting brackets to
be used for both ceiling & wall mounting.
2400
2400
CEILING MOUNTING MINIMUM
300
CEILING MOUNTING MINIMUM
CLEARANCE TO FLOOR
300
CLEARANCE TO FLOOR
12"
12"
INSTALLATION CLEARANCES
FOR 4000W & 6000W MODELS
4000W & 6000W models must be installed with the minimum installation clearances shown in below diagrams. 4000W
& 6000W models are supplied with long mounting brackets to be used for both ceiling & wall mounting.
Alternatively, short mounting brackets can be used for wall mounting of the 4000W & 6000W models to position the
heater closer to the wall. Short mounting brackets must be purchased separately.
2400
2400
450
CEILING MOUNTING MINIMUM
450
CEILING MOUNTING MINIMUM
CLEARANCE TO FLOOR
18"
CLEARANCE TO FLOOR
18"
!
WARNING
DO NOT MOUNT THE HEATER VERTICALLY!
For outdoor installation heater must be mounted with
face of heater angled down.
For longest product life & to maintain product
appearance mount heater under cover & protect from
rain & weather whenever possible.
!
WARNING
ES MODELS MUST NOT BE MOUNTED WITH CEILING
RECESS MOUNTING KITS.
300
300
12"
12"
1800/96" (8')
1800/96" (8')
WALL MOUNTING MINIMUM
WALL MOUNTING MINIMUM
CLEARANCE TO FLOOR
CLEARANCE TO FLOOR
300
300
12"
12"
1800/96" (8')
1800/96" (8')
WALL MOUNTING MINIMUM
WALL MOUNTING MINIMUM
CLEARANCE TO FLOOR
CLEARANCE TO FLOOR
www.bromicheating.com
7