Select the best location
Location for Installing Indoor Unit
• Where there is no obstacle near the air outlet
and air can be easily blown to every corner of
room.
• Where piping and wall hole can be easily
arranged.
• Observe the required distance from ceiling and
wall according to the installation diagram.
• Where the air filter can easily be removed.
• Keep the unit and remote control 1m or more
from television, radio etc.
• To prevent the effects of a fluorescent lamp,
keep the unit as far as possible from it.
• Do not put anything near the air inlet that could
obstruct it.
• In a place that can bear the weight and will not
increase operating noise and vibrations.
• The indoor unit is not suitable to be installed in
areas used for laundry.
Location for Installing Outdoor Unit
• Install in a convenient and well-ventilated place.
• Avoid installing it where flammable gas could
leak.
• Observe the required distance from the wall
according to the installation diagram.
• The distance between Indoor and outdoor unit
should be 5 meters and can go up to maximum
15 meters with additional refrigerant charge.
• Do not install the outdoor unit in a dirty or
greasy place, near a vulcanization gas exit.
• Avoid installing it at the roadside where it could
be soiled with muddy water.
• A fixed base where operating noise will not
increase.
• Where the air outlet is not obstructed.
• The installation position shall be able to
withstand the weight and vibration of the
outdoor unit and ensure safe installation;
• Where drained water does not become any
problem.
Model
Standard
tubing
Length (m)
FM20ODU
5+5
WA2
FM24ODU
5+5+5
WA2
FM36ODU
5+5+5+5
WA2
Limit of
Limit of Total
Each Indoor
Tubing
Unit Tubing
Lenght (m)
Length (m)
20
40
20
60
25
60
48
Indoor unit
Pipe length is
3~20 meters
Indoor unit
Limit of
Elevation
Difference H
(m)
10
10
10
Pipe length is
3~20 meters
Outdoor unit
Outdoor unit
Extra
refrigerant charge
(g/m)
15 (When total piping
length is over 15m)
15 (When total piping
length is over 20m)
15 (When total piping
length is over 20m)