FOR BATTERY TOOLS
The ambient temperature range for the use and storage of tool and battery is 0
The recommended ambient temperature range for the charging system during charging is 0

ENVIRONMENTAL PROTECTION

Waste electrical products must not be disposed of with household waste. Please recycle where facilities exist. Check
with your local authorities or retailer for recycling advice.
TROUBLE SHOOTING
Symptom
Tool will not start when operating the
on/off switch.
Cutting depth is less than that is set.
Blade spins or slips
16
16
Blade will not cut a straight line.
Blade kicks back when beginning
a cut
Lithium-Ion Cordless Circular Saw
Possible Causes
Battery park not plugged in.
Battery park is powered off.
Carbon brush has worn down
Sawdust accumulated at the rear
of the base.
Blade is not tightly engaged with
the spindle.
Blade is dull.
Blade is not mounted properly.
Saw is not being guided properly.
Blade is not spinning fast enough
o
C-45
o
C.
o
o
C-40
C.
Possible Solution
Check to make sure battery park is
connected well into a working outlet
Charging the battery.
Replace the carbon brush using a
qualified maintenance person.
Shake out sawdust. Consider connecting
a vacuum for dust collection.
Remove the blade, and reassemble it as
described in SAW BLADE ASSEMBLY
AND REMOVING section.
Mount a new, sharp blade on the saw.
Check that blade is properly mounted.
Use a parallel guide.
Allow the saw blade to reach full speed
prior to beginning a cut in the material.