Battery Removal

UPS System – Internal Battery Removal
1
Remove the six front screws from the front bezel, then
remove the bezel from the UPS. Hang the bezel on the
available hook.
Note: The front panel display has an attached ribbon cable
that extends from the UPS to the front bezel. Make sure to
keep this cable out of the way when opening and closing the
battery door, or use a screwdriver to detach the display from
the bezel.
2
Loosen the two captive screws securing the battery door.
3
Open the battery door. Ensure the Smart battery
communications cable is safely out of the way when
opening the battery door and removing the battery
trays.
4
Using the handles attached to each tray, slightly pull out
the old battery pack trays and disconnect the
communication cable.
5
Once the communication cables have been
disconnected. Remove both old battery trays from the
UPS. Proceed to R.B.C Installation section if no
external battery packs are being used.
1
2
4
5
3