5.4
Program switching times
A maximum of 10 switching time programmes are available.
These can be set in minimum 1-minute increments.
•
Make sure that the set switching times do not overlap, especially if you set up weekly pro-
grammes.
•
If switching times overlap, the timer performs the ON or OFF function according to the pro-
grammed switching times.
•
If OFF (turn off) and ON (turn on) are programmed simultaneously by 2 different program-
mes, OFF (turn off) will be executed.
•
Programming is only available in AUTO mode.
1. Press the TIMER button briefly.
The display shows >> ON_1 <<.
2. Set the switch-on time of the 1st switching time programme using the WEEK, HOUR and
MINUTE buttons.
3. Briefly press the TIMER button again.
The display shows >> OFF_1 <<.
4. Set the switch-off time of the 1st program by WEEK, HOUR, and MINUTE button.
5. Press the TIMER button briefly again to finish the 1st program setting.
The display shows >> ON_2 <<.
6. Repeat steps 1 to 5 to program further switching times.
7. Press the CLOCK button to leave the program menu.
The time switch is now set up.
Example:
The time switch shall switch on at 17:15 clock and switch off at 22:30 clock each day.
1. Press the TIMER button briefly.
The display shows >> ON_1 <<.
2. Press the WEEK button repeatedly until the display shows
>> MO, TU, WE, TH, FR, SA, SU <<.
3. Press the HOUR button repeatedly until the display shows >> 5:00 clock << or
>> 17:00 clock <<.
4. Press the HOUR button repeatedly until the display shows >> 5:15 clock << or
>> 17:15 clock <<.
5. Press the TIMER key once briefly.
The display shows >> OFF_1 <<.
6. Repeat steps 3. to 5. until the display shows >> 10:30 clock << or >> 22:30 clock << is di-
splayed.
If you press and hold the HOUR or MINUTE button, you can set times faster.
5.5
Manual Settings
The operating mode cannot be changed during programming.
•
Press the ON/AUTO/OFF button to change the operating mode.
The set programmes are only executed in AUTO mode. In ON mode, the connected unit
is always switched on, in OFF mode it is always switched off. When the mode is changed
from ON to AUTO, the connected appliance remains switched on until the next program-
med switch-off point.
EN
14