• Make sure that there is an access to the
mains plug after installation.
• Do not pull the mains cable to disconnect
the appliance. Always pull the mains plug.
• The appliance must not be connected with
an extension cable, an adapter or a multiple
connection (risk of fire). Check that the
ground connection is in conformity with the
standard and regulations force.
• The power cable must be placed in such a
way that it does not touch any hot part.
• Connect the appliance to the mains with a
device that lets to disconnect the appliance
from the mains at all poles with a contact
opening width of minimum 3 mm, eg. auto-
matic line protecting cut-out, earth leakage
trips or fuse.
• None of a parts of the connection cable can
not get a temperature 90 °C. The blue neu-
tral cable must be connected to the terminal
block label with "N". The brown (or black)
phase cable (fitted in the terminal block con-
tact marked with "L") must always be con-
nected to the live phase.
Replacement of the connection cable
To replace the connection cable use only
H05V2V2-F T90 or equivalent type. Make sure
that the cable section is applicable to the volt-
age and the working temperature. The yellow/
green earth wire must be approximately 2 cm
longer than the brown (or black) phase wire.
Building In
min. 600 mm
min. 55 mm
30 mm
6
All manuals and user guides at all-guides.com
min. 650 mm
550 mm
B
A) supplied seal
B) supplied brackets

Possibilities for insertion

Kitchen unit with door
The panel installed below the hob must be easy
to remove and let an easy access in case a
technical assistance intervention is necessary.
30 mm
a
min 20 mm
60 mm
(max 150 mm)
b
a) Removable panel
b) Space for connections
A