2.4 Names of the Components

See Fig. 1
1
Mode
2
Time and date
Battery status
3
Measured value
4
Selected valve and valve setting
5
Menu bar
6
7
Power on/off / enter key
8
Line up / line down keys
Escape / return key
9
See Fig. 2
Screen and keyboard (details see
10
above)
Device housing with rubber padding
11
Cover for hose and temperature
12
sensor connections
See Fig. 3
Battery cover
13
Typeplate and calibration mark
14
(attached after first re-calibration)
Cover for hose and temperature
15
sensor connections
See Fig. 4
16
Socket for battery charger
See Fig. 5
Infrared transmitter
17
USB socket
18
See Fig. 6
Socket T
19
Socket T
20
21
Connection for high pressure hose
22
Connection for low pressure hose

2.5 Charging Batteries

Plug battery charger into line voltage power socket
and into power socket on right side of device (see Fig.
4, item 16)
Batteries are charged. Charging is indicated by a light
on the battery charger with the following states:
– Yellow: not connected or initialising
– Orange: fast charge
– Green/yellow: top-off charge
– Green: trickle charge
– Orange/green: error
Full charge of original batteries takes approx. three
hours
Use dedicated battery charger supplied with device
only
Charge batteries indoors or in a sheltered
environment within specified ambient temperature
only
MU2H-2323GE25 R0620
for temperature sensor
1
for temperature sensor
2
GB
Batteries will be exhausted if left for a long period of
time after being charged
Battery charger can be used as mains power supply
for device, e.g. during data logging, if device is
equipped with rechargeable batteries
Device does not work when not equipped with
batteries. Also not when battery charger is connected
WARNING!
Battery charger must NOT be used when device is
equipped with non rechargeable batteries

2.6 Replacing batteries

The lid of the battery compartment is opposite the display.
Remove lid by pushing down tab on topside of device
and sliding lid off
Remove old batteries. Pull ribbon to remove lower two
batteries
Insert new batteries. Pay attention to correct polarity
as indicated in battery compartment. Place ribbon
below lower batteries
Replace lid. Ensure tab snaps back into place
Instead of rechargeable batteries four standard AA
size dry batteries can be used alternatively. Never try
to recharge standard dry batteries. Never mix
standard dry batteries with rechargeable batteries
2.7 Setup
2.7.1 Setting Device Clock
To set or change time and date proceed as follows:
Operation
Switch on device
Device carries out zero calibration and then automatically
switches to measuring mode
Stop ongoing
measurement
Enter main menu
Scroll down to menu
item "Setup"
Enter Setup menu
"Time" is first item in setup menu
Move cursor into data
field until first digit to be
changed is highlighted
Change value of digit
Move to next digit
Change value of digit
3
Command
Key
-
ON
STOP
ON
MENU
ESC
DOWN
È
OK
ON
ON
Æ
UP/DOWN
È
ON
Æ
UP/DOWN
È