1
Introduction
1.1 How to use these Instructions
The Operating and Setup Instructions include step by step
instructions for setup and operation functions of the
BasicMes-2. The step by step instructions are normally
structured as follows:
•
Description of function
•
Step by step instructions how to access function as
displayed below:
Operation
Stop ongoing measurement STOP
Measurement can be carried
on later
where
– "Operation" is action to be carried out
– "Command" is command in menu bar at bottom
end of screen above corresponding keys
– "Key" is corresponding key (see Table 1 further
below)
•
Step by step instructions how to input data or modify
existing data
Number in Fig. 1
6
7
8
9
1.2 Safety Guidelines
1.
Follow the installation instructions.
2.
Use the appliance
• according to its intended use
• in good condition
• with due regard to safety and risk of danger.
3.
Note that the appliance is exclusively for use in the
applications detailed in these installation instructions
(see 3 Technical Data). Any other use will not be
considered to comply with requirements and would
invalidate the warranty.
4.
Please take note that any assembly, commissioning,
servicing and adjustment work may only be carried
out by authorized persons.
5.
Immediately rectify any malfunctions which may
influence safety.
Command Key
ON
Terminology used in
instructions
Menu bar
ON key
UP/DOWN key
ESC key
GB
2
General information
2.1 Intended use
The BasicMes-2 handheld flow measurement computer is a
high-precision multifunctional device for measuring and
recording differential pressure and temperatures in hydronic
heating and cooling systems.
2.2 Before use
2.2.1 Before first use
The BasicMes-2 is supplied ready for use with English as
default language, however:
•
Batteries have to be inserted and may require
charging
•
Date and time have to be set
•
Other options may require changing
•
Check that all accessories are included
2.2.2 Before any use
•
Check that device is in good working order
•
Check that batteries have enough charge for
operations intended
2.3 Scope of Delivery
Item
VM242A BasicMes-2
handheld flow measuring
device
Four rechargeable AA size
NiMH batteries
Lanyard
Bypass assembly with
installed hoses and quick
connections
Mains power unit
USB cable
Adapter Rectus 21 onto
®
Resideo SafeCon
quick
connection
Adapter Rectus 21 onto 3/4"
internal thread
Multilingual setup and
operating instructions
CD with instructions and user
software
Carry case with foam insert
2
Spare part ordering
number
VMS242A001
N/A
N/A
VMS242A002
VMS242A006
VMS242A005
VA2500B001
VMS242A004
MU2H-2321GE25
EN9H-2321GE251
VMS242A007
MU2H-2323GE25 R0620